Troubleshooting
⚠
WARNING:
Disconnect the Tire Changer from power and incoming
before performing any
maintenance
. Take whatever steps are necessary to make sure the unit cannot
be re-energized while maintenance is being performed on it (such as
Lockout/Tagout). The unit uses pneumatic and electrical energy; if your organization
has Lockout/Tagout policies, make sure to implement them before troubleshooting
the Tire Changer.
Issue
Action to Take
The Turntable does not move when
you step on the Turntable Foot
Pedal.
Make sure the unit is getting power.
The unit is not getting power.
Have a licensed, certified Electrician check the electrical path
from the supplied cord to the power source. If any issues are
found, have them fixed. Refer to
additional information.
No air comes out when you step on
the Inflate Foot Pedal.
Make sure the unit is correctly connected to a working
incoming air source.
It is difficult to secure Tires when
clamping externally.
Use the Restraint Cone to press the Tire down so the Clamps
correctly grab the Rim of the Wheel. R76ATR only.
The Inflation Gauge is not working
correctly.
Check the accuracy of the Inflation Gauge with a professional
gauge. Fix immediately if the Inflation Gauge is not working
correctly.
The Assist Arms (R76ATR only)
move up and down slowly or make
odd noises when moving.
Grease the Assist Tower Post, it has run out. Refer to
If you continue to have problems with your Tire Changer, visit
BendPak Ranger at (805) 933-9970
.
Summary of Contents for R76LT
Page 58: ...R76 Series of Tire Changers 58 P N 5900346 Rev C Dec 2019 Labels...
Page 59: ...R76 Series of Tire Changers 59 P N 5900346 Rev C Dec 2019...
Page 87: ...R76 Series of Tire Changers 87 P N 5900346 Rev C Dec 2019 Maintenance Log...
Page 88: ...1645 Lemonwood Drive Santa Paula CA 93060 USA 2019 BendPak Inc All rights reserved bendpak com...