Connect the Air Lines
Connect the Air Lines to the Fittings on the Unit. The Air Line comes as one long roll of tubing; you
need to cut it into sections of the right length.
Each connector on the Elbow and Straight Compression Fittings have a Nut, Ferrule, and Threads. The
Nut holds the tubing and Fitting together. The Ferrule compresses when you tighten the Nut on the
Threads to make a secure connection.
Important
:
Ferrules can only be used once
. When you tighten the Nuts on the Threads,
the Ferrule gets compressed; it changes shape and
cannot
be used again.
The following drawing shows the Air Line connections to make to the Unit.
To install the Air Lines
:
1.
Attach the Air/Oil Regulator and Bracket to the Enclosure using two M4 x 42 Screws.
2.
Cut a piece of tubing of appropriate lengths for each of the five Air Line segments.
3.
Connect the various pieces of tubing to the Straight Fitting and Elbow Fittings, as shown above.
Make sure to route the Straight Fitting tubing through the opening and behind the Air/Oil Regulator.
4.
Securely tighten all the connections.
5.
Connect your customer-supplied air pressure to the “Air In”, a minimum of 125
–
175 psi.
Summary of Contents for RP-20FC
Page 14: ...RP 20FC Oil Filter Crusher 14 P N 5900011 Rev B1 February 2021 Labels ...
Page 15: ...RP 20FC Oil Filter Crusher 15 P N 5900011 Rev B1 February 2021 Parts Diagrams ...
Page 16: ...RP 20FC Oil Filter Crusher 16 P N 5900011 Rev B1 February 2021 ...
Page 17: ...RP 20FC Oil Filter Crusher 17 P N 5900011 Rev B1 February 2021 Maintenance Log ...
Page 18: ...RP 20FC Oil Filter Crusher 18 P N 5900011 Rev B1 February 2021 Maintenance Log ...
Page 19: ...RP 20FC Oil Filter Crusher 19 P N 5900011 Rev B1 February 2021 Maintenance Log ...