Connecting the turn table
Before scanning on turn table it`s necessary to install table driver, to plug it in and to
connect the table with the computer via USB-cable.
Scanner may be equipped with different types of turn tables, with additional power
supply or without it, and depending on the controller, the name of the connected device
can be different, for example
Silicon Labs
,
Arduino Uno
,
Rangevision Table
and so on.
For the correct operation of Rаngevisiоn 3D scanner you will need to setup your
computer. This procedure is performed once before the first use of the scanner.
Setting up your computer for the work with the
scanner
9
For checking efficiency of the table, turn it for a little angle. On the menu choose
Adjustment
Table calibration
. Enter the angle number and press
Turn
. The table must
rotate clockwise, viewed from above. If the table rotates in another direction, change
the parameter -
Change the direction
in configuration settings.
Apart from other modes, before using turn table for scanning it`s necessary to
evaluate its axis (to perform table calibration). It`s done in order that the scanner could
acquire positioning of table axis for automatical fragment registration. Additional
calibration of table is necessary, if during scanning the reciprocal positioning of the
table and the scanner changed.
In order to avoid problems with scanner functioning it`s necessary to switch off
screensaver and sleeping mode.
Click by the right mouse button on the desktop choose
Personalization
Screensaver
, switch off the screensaver and transition of the computer to sleeping
Configuring computer parameters
mode.