Initial setup of cameras and lenses
When you first set up the scanner, image from the cameras may not be in focus or can
be too bright or too dark due to different external lighting conditions. Adjust camera
lenses, so that the brightness is acceptable: without the red overexposed areas and not
too dark.
Lens adjustment is carried out by rotating the ring on the objective. Loosen (do not
unscrew!) the retention screw and rotate the ring.
Lens adjustment is carried out by the following elements:
1. The iris tuning ring
2. The iris ring retention screw
3. The focus tuning ring
4. The focus ring retention screw
Do not completely remove the retaining screws of the lens rings, it is enough just to
loosen them. After you finished tuning the lens, lock the adjustment rings with the
screws provided.