Section 5:  MAINTENANCE 

AH-10-01 : Vector Solo SPM 

When cleaning the applicator, a suitable solvent for cleaning depends on the part(s) of the applicator to be cleaned and 
the material that needs to be removed. ITW Ransburg recommends that all exterior cleaning be done with non-polar  
solvents to prevent a conductive residue on critical components. We also understand that some of these solvents do not 
always meet the cleaning needs of some materials. If conductive polar solvents are used to clean the applicator       
components, all residue must be removed using a non-conductive non-polar solvent (i.e. high flash Naphtha). If there 
are any questions as to what solvents are best for cleaning , contact your local ITW Ransburg distributor and/or your 
paint supplier. 
 
The Vector applicator, air hoses, and fluid hose assemblies should not be submerged or soaked in solvent. However, 
the outer surfaces of these items can be wiped with a suitable cleaning solvent. The items that cannot be soaked are 
noted throughout this manual. All electrical components cannot be cleaned or soaked in any solvents. 

WARNING 

 
The user MUST read and be familiar with the safety instructions in this manual.

 

If compressed air is used in cleaning, REMEMBER that high pressure air can be dangerous and should 
NEVER be used against the body. It can blind, deafen, and may even penetrate the  
skin. If used for cleaning equipment, the user should wear safety glasses.

 

ALWAYS turn the control unit's power off prior to cleaning and servicing the equipment.

 

Be SURE  the power is OFF and the system is grounded before using solvent to clean ANY  
equipment.

 

DO NOT operate a faulty applicator!

 

Use of ungrounded or plastic containers may cause fire or explosion.

 

Cleaning of the exterior surface of the applicator should be done with non-polar solvents. If  
cleaning requires the use of polar solvents, the applicator should be wiped down with non-polar 
 solvent prior to going back into use. Using polar solvents will leave a semi-conductive film on  
the surface of the applicator that will effect efficiency of the applicator and cause damage to the 
components.

 

  

Summary of Contents for 80011

Page 1: ...RECAUTIONS starting on page 1 and all instructions in this manual Keep this Service Manual for future reference MODEL 80011 Vector Solo SPM 80012 Power Supply Control Unit PRODUCT MANUAL AH 10 01 Vect...

Page 2: ...2 NOTES...

Page 3: ...ecifications Section 3 INSTALLATION 11 Mounting the Control Unit Control Unit I O and Ground Connections Vector Solo SPM Gun Connections Section 4 OPERATION 13 Operation of the Control Unit Section 5...

Page 4: ...the WARNINGS and safety requirements for operating and servicing the equipment are followed The user should be aware of and adhere to ALL local building and fire codes and ordinances as well as NFPA...

Page 5: ...the atomizer must be turned off prior to cleaning flushing or maintenance When using solvents for cleaning Those used for equipment flushing should have flash points equal to or higher than those of t...

Page 6: ...m which requires correction Always turn the control panel off prior to flushing clean ing or working on spray system equipment Ensure that the control panel is interlocked with the ventilation system...

Page 7: ...t must NOT be used in Class I Division 1 or 2 locations Electrical Discharge High voltage equipment is utilized Arcing in areas of flammable or combustible mate rials may occur Personnel are exposed t...

Page 8: ...en training in accordance with the requirements of NFPA 33 2009 Edition Instructions and safety precautions must understood prior to using this equipment Comply with appropriate codes governing ventil...

Page 9: ...ule alternator This position is used when no voltage is desires such as targets that exhibit Fara day cage effects The third position directs air to the infinitely adjustable air regulator then to the...

Page 10: ...66 mm Applicator Specifications Maximum Air pressure to Applicator 7 5 bar 100 psig Maximum Fluid pressure to Applicator 7 5 bar 100 psig Applicator Weight less Cable 700 g Maximum Output Voltage 45...

Page 11: ...ing distances required I O CONNECTIONS Connect the main air supply to the inlet of the control unit as shown below Connect the air hose to the applicator from the outlet of the control unit Appropriat...

Page 12: ...th ground as shown in the picture below For the unit to properly function a true earth ground connection must be made Ground Connection VECTOR SOLO SPM GUN CONNECTIONS Connect fluid air and cable to t...

Page 13: ...um of 3 5 bar 50 psig for the unit to properly function The control unit switch has three positions Each position provides a different applicator function The first position is the all functions OFF o...

Page 14: ...an Air ON FULL VOLATGE PRODUCTION The control unit also has an infinitely adjustable atomization fan air pressure adjustment By adjusting the regulator knob the pressure to the applicator that control...

Page 15: ...items that cannot be soaked are noted throughout this manual All electrical components cannot be cleaned or soaked in any solvents WARNING The user MUST read and be familiar with the safety instructi...

Page 16: ...ean and undamaged NEVER soak or submerge the electrical components of the applicator i e barrel power module or handle Damage and failure may occur NEVER remove the fluid nozzle assembly while paint i...

Page 17: ...17 AH 10 01 Vector Solo SPM VECTOR SOLO SPM GUN PARTS Section 6 PARTS LIST...

Page 18: ...18 AH 10 01 Vector Solo SPM VECTOR SOLO SPM GUN PARTS...

Page 19: ...19 AH 10 01 Vector Solo SPM VECTOR SOLO SPM NEEDLE SHAFT PARTS...

Page 20: ...er supplies control units etc is one 1 year from date of purchase WRAPPING THE APPLICATOR IN PLASTIC WILL VOID THIS WARRANTY ITW RANSBURG S ONLY OBLIGATION UNDER THIS WARRANTY IS TO REPLACE PARTS THAT...

Page 21: ...21 AH 10 01 Vector Solo SPM NOTES...

Page 22: ...Assistance 320 Phillips Ave Toledo Ohio 43612 1493 Telephone toll free 800 233 3366 Telephone 419 470 2021 Fax 419 470 2040 Technical Support Representatives can direct you to the appropriate telepho...