79727-XX Length
T-40 AIR CAP 80240-00
Static Pressure at Wall
bar
Dynamic Pressure at Wall
psig
bar
psig
79727-XX Length
V-65 AIR CAP 80265-00
Static Pressure at Wall
bar
Dynamic Pressure at Wall
psig
bar
psig
30 m
4.5
65
4.3
62
20 m
4.3
62
3.9
57
15 m
4.1
60
3.8
55
10 m
4.0
58
3.7
53
30 m
4.5
65
4.1
60
20 m
4.1
60
3.9
56
15 m
4.0
59
3.7
54
10 m
3.8
55
3.6
52
10. Turn on voltage and trigger applicator. Green light
should be on.
(Horns Horizontal)
11. Adjust fluid pressure and air pressure as required
to achieve finish.
12. Adjust air cap position as required.
79727-XX Length
C-31 AIR CAP 80231-00
Static Pressure at Wall
bar
Dynamic Pressure at Wall
psig
bar
psig
30 m
3.8
55
3.6
52
20 m
3.7
53
3.4
50
15 m
3.6
52
3.3
48
10 m
3.5
50
3.2
47
AH-15-01.2
22
Ranflex Applicators
-
OPERATION