GB-36
RANSOMES DIABLINE
SAFETY AND OPERATORS MANUAL
B.1.6 Batteries central fi lling
Thanks to this system, you can easily make the batteries water level :
•
Connect the removable tank to the mouth located on the right of the batteries compartment and
keep it higher than it.
•
Open the tap and wait until the red roller stop
•
Close the tap and disconnect the can.
NOTE
We recommend checking the electrolyte levels
every 15 days (hot weather) or every 3 weeks
(regular use).
If the check point gauges on top of the caps
are red the level is full, if they are half or not
visible they need topping up.