GB-48
RANSOMES DIABLINE
SAFETY AND OPERATORS MANUAL
B.2.6.1 Charger - NG1
Two chargers are available:
Standard charger
13A (7-8 hours)
Fast charger 16A
When charging:
0-5 hours Red }
5-8 hours Amber}
lights on charger
10-15 hours
Green }
60-70%
When fan switches off battery is fully charged -
62/63V peak battery voltage
If disconnected during charge cycle a warning beep
can be heard.
Note: If the battery pack goes below 20% charge
then the charger fi tted to the machine cannot detect
the pack and will not switch on. If this occurs a
remote charger will be required to boost the charge
to allow the on board charger to be used
Note: Machine should be charged every day if it
has been used whether for 1 hour or 12 hours.
LED State
Alarm Type
Description (Action)
RED fl ash
Battery Presence
Battery disconnected or not in conformity. (Verify the connection and the
nominal voltage).
YELLOW fl ash
Thermal Sensor
The thermal sensor is disconnected during the recharge or it is out
working range. (Verify the connection of the sensor and measure the
temperature of the battery).
GREEN fl ash
Timeout
Phase 1 and/or Phase 2 have a duration in excess of the maximal al-
lowed. (Verify the battery capacity).
RED-YELLOW fl ash
Battery Current
Loss of output Current control. (Failure of the control logic).
RED-GREEN fl ash
Battery Voltage
Loss of output Voltage control. (Battery disconnected or failure of the
control logic).
RED-YELLOW-GREEN fl ash
Thermal
Overheating of semiconductors. (Verify the fan operation)
B.2.6.2 Charger - NG3
RED LED
shows that the battery is in the initial charging phase.
YELLOW LED
shows that the battery charger has reached 80% of charge.
GREEN LED
shows that the battery has reached 100% of charge.
ALARMS
An two-tone audible message and the fl ashing LED shows that an Alarm
situation has occurred:
100%
START
80%
80%
When there is an alarm the battery charger stops supplying current.
B.2.6 Charger