Start-up and beginning operation
The cooling unit and lighting are switched on and off using the switches shown in Fig 3.
The temperature inside is adjusted by the temperature controller, according to the
instructions in p. 10. After switching the device on, leave it empty until it turns off for the
first time. Now it is ready to be filled with products. The condensate container should be
emptied as needed.
Place the products on the shelves so that they do not protrude behind the shelf contour
– this is necessary to ensure proper air circulation inside (Fig 4). The maximum shelf
load is 30 kg.
Never put warm/hot products in the device because this causes an extended
temperature increase inside the device and can even create a fault. A temperature
increases after filling the multideck refrigerated display with warm/hot products is not
evidence of a failure and does not constitute a basis for submitting a claim.
8. MAINTENANCE
After disconnecting the device from power supply, the general maintenance should be
done by the user, as follows:
1. washing with water of the temperature not more than +40°C with addition of natural
cleaning agents.
To wash and clean the device it is forbidden to use agents
containing of chlorine and sodium of various varieties, which destroy the
protective layer and components of the device!
Any residual glue or silicone on
the metal parts of the device should be removed only with gasoline (not applicable to
plastic components!). Do not use other organic solvents.
2. removing impurities from the condenser by means of vacuum cleaner
(from up to
down - along the fins)
at least once a month so that the flow of the cooling air
through the condenser fins is not hampered.
Not following the above instructions causes increased energy consumption,
decreased refrigeration efficiency of the device and eventually result in aggregate
overheating, which consequently may lead to failure.
While cleaning the condenser be careful not to deform the fins.
Do not wash the device with a water jet.
It is not advisable to clean the condenser with a brush as it causes impurities
penetration deep into the condenser fins and finally block the air flow
completely.