background image

 

 
 
Start-up and beginning operation 

The cooling unit and lighting are switched on and off using the switches shown in Fig 3. 
The temperature inside is adjusted by the temperature controller, according to the 
instructions in p. 10. After switching the device on, leave it empty until it turns off for the 
first time. Now it is ready to be filled with products. The condensate container should be 
emptied as needed. 
Place the products on the shelves so that they do not protrude behind the shelf contour 
– this is necessary to ensure proper air circulation inside (Fig 4). The maximum shelf 
load is 30 kg. 
Never put warm/hot products in the device because this causes an extended 
temperature increase inside the device and can even create a fault. A temperature 
increases after filling the multideck refrigerated display with warm/hot products is not 
evidence of a failure and does not constitute a basis for submitting a claim. 

 

8. MAINTENANCE 

 

After disconnecting the device from power supply, the general maintenance should be 
done by the user, as follows: 
1. washing with water of the temperature not more than +40°C with addition of natural 
cleaning agents. 

To wash and clean the device it is forbidden to use agents 

containing of chlorine and sodium of various varieties, which destroy the 
protective layer and components of the device!

 

Any residual glue or silicone on 

the metal parts of the device should be removed only with gasoline (not applicable to 
plastic components!). Do not use other organic solvents.

 

2. removing impurities from the condenser by means of vacuum cleaner 

(from up to 

down - along the fins)

 at least once a month so that the flow of the cooling air 

through the condenser fins is not hampered.  
Not following the above instructions causes increased energy consumption, 
decreased refrigeration efficiency of the device and eventually result in aggregate 
overheating, which consequently may lead to failure. 

While cleaning the condenser be careful not to deform the fins.

  

Do not wash the device with a water jet.

  

It is not advisable to clean the condenser with a brush as it causes impurities 
penetration deep into the condenser fins and finally block the air flow 
completely. 

 

 
 

 
 

 
 
 

 
 
 
 
 

Summary of Contents for RCh-O

Page 1: ...1 TRANSLATED FROM ORIGINAL USER MANUAL MODULAR MULTIDECK REFRIGERATED DISPLAY RCh O RCh SR 11 2021 EN...

Page 2: ...roduct characteristics 5 3 Cooling system diagram 5 4 Wiring system 5 5 Wiring system diagram 6 6 Drawings 7 7 Positioning start up and operation 9 8 Maintenance 10 9 Transport and equipment 11 10 Tem...

Page 3: ...ing of the device to the mains may result in an electric shock 2 In the event of sparks or breakdowns immediately disconnect the device from the power supply by pulling the plug from the socket and ca...

Page 4: ...l sliding doors 196 70 device dimensions see table in p 2 Important information on the rating label of each device In the case of contact with the service department prepare the following data for eff...

Page 5: ...for the service 4 The device should be connected to a separate properly made electrical circuit protected by a fuse no greater than 16 A with a B characteristic ended with a socket with a protective p...

Page 6: ...protection 4 starting relay 5 starting capacitor 6 run capacitor 7 compressor s electric node 8 condenser fan 9 case of evaporator fans 10 evaporator fans 11 main switch 12 lighting switch Fig 1 Elect...

Page 7: ...Lighting switch Electronic temperature controller Fig 4 Cross section RCh O sliding doors night blind shelf support air duct insulation bottom fan compressor LED lighting shelf shelf edge strip night...

Page 8: ...r the whole length 40 kg but maximum load of one hook 10 kg It is allowed to install only three crossbars one below the other It is possible to install crossbar closer to the back Only one crossbar is...

Page 9: ...before start up Place the device in the required location and make sure all the feet are fully screwed almost as far as they can go Then unscrew the feet and using a level adjust legs until the device...

Page 10: ...eral maintenance should be done by the user as follows 1 washing with water of the temperature not more than 40 C with addition of natural cleaning agents To wash and clean the device it is forbidden...

Page 11: ...mpressor s start up is delayed because of protective procedure It flashes in the cycle two flashes break when there is continuous operation mode activated 2 FAN The symbol is visible when there are ev...

Page 12: ...g power supply of the controller on will cause return to the parameters fabric settings there will be shown CF symbol on the display In the parameters setting mode its pressing changes the information...

Page 13: ...arameter setting increase or decrease setting value by means of the UP and DOWN switches press the SET switch to temporarily save the entered new value it will cause as well return to the parameters l...

Page 14: ...ended after exceeding the maximum duration rather than when reaching the end defrost set point The message disappears when the next defrost ends correctly EF displayed during operation or on power up...

Page 15: ...hamber loud operation of the aggregate characteristic clicking coming out of the aggregate chamber every few minutes Goods loaded in the device chamber should be initially cooled up to maximum 4 C abo...

Page 16: ...000009031 tel 48 81 742 53 10 do 14 e mail rapa rapa lublin pl Service tel 48 81 718 46 08 e mail service rapa pl www rapa pl en The package should be removed according to the regulations of environme...

Reviews: