SWITCHES DESCRIPTION
Information: Short pressing of any of the switches causes appearance of message
related to the currently active function..
7. UP / ON OFF
During normal operation of the controller; pressed for longer than 3 sec. will cause
change of controller ON/OFF operation state, pressed along with the “DOWN”
switch at the same time for longer than 3 sec. will cause activation or deactivation
of continuous operation function (after pressing there will be shown on the display
“CC” symbol). In the parameters setting mode: enable going to the next
parameters settings. During setting parameter values: it causes parameter value
increase.
8. SET / MUTE
Pressed during normal controller operation switches the alarm sound signal off;
pressed for longer than 3 sec. shows setting point; pressed along with the
“DOWN” switch at the same time while switching power supply of the controller on
will cause return to the parameters fabric settings (there will be shown “CF”
symbol on the display). In the parameters setting mode: its pressing changes the
information shown on the display: parameter name/parameter value, pressed for
longer than 3 sec. will cause saving of the set parameters. During setting
parameter values: pressed it will cause saving of the entered parameter value.
9. DOWN / DEFROST
During normal operation of the controller; pressed for longer than 3 sec. will cause
switching on/off of the manual defrost mode. In the parameters setting mode: it
allows to go to previous parameter setting. During setting parameter values: it
decreases setting value.
Set point setting (desired temperature value)
To view and modify the set point:
>
press the “SET” switch for 1 sec. – the set value will start flashing;
>
increase or decrease the value using the “UP” or “DOWN” switches;
>
press the “SET” switch to confirm the new value
If the “SET” switch is not pressed for 60 sec., then the controller returns to
previous settings
.