11. INTERFERENCES
The most often occurring interferences of the device operation:
12. NOTES
1. Attempts to repair the device on your own and not following the instructions
described in the user manual as for equipment connection and use will result
in the device malfunction.
2. The manufacturer is not liable for damages resulting from the use of the device
in a manner inconsistent with the information contained in hereby user manual.
Reasons
Symptoms
Solution
Contaminated
condenser
>
Visible dust layer on the condenser fins,
>
hot air coming out of the aggregate chamber,
>
loud operation of the aggregate,
>
characteristic "clicking" coming out of the
aggregate chamber every few minutes
Before cleaning of the condenser it is
necessary to switch the device off.
Impurities on the condenser should be
removed by means of vacuum cleaner
equipped with brush, gently along fins to
not to bend the lamella.
Device loaded with
warm products
>
hot air coming out of the aggregate chamber,
>
loud operation of the aggregate,
>
characteristic "clicking" coming out of the
aggregate chamber every few minutes
Goods loaded in the device chamber should
be initially cooled up to m4°C above
the storage temperature .
Too high ambient
temperature
>
hot air coming out of the aggregate chamber,
>
loud operation of the aggregate,
>
characteristic "clicking" coming out of the
aggregate chamber every few minutes
Ambient temperature for proper operation of
the device should not exceed respectively: for
3rd climatic class +25°C.
Improper goods
distribution in
cooling chamber
>
high temperature of products
The goods should be placed as described in
user manual
.
External source of
heat causing the
abnormal
operation of the
device
>
hot air coming out of the aggregate chamber,
>
loud operation of the aggregate,
>
characteristic "clicking" coming out of the
aggregate chamber every few minutes
External source of heat might be any other
device that emits heat such as gas burner,
heater, other device equipped with a
refrigerated aggregate etc. It is necessary to
pay attention if above mentioned examples
may have influence on the deterioration of
device operation conditions.