23
5.3
Position Setup Items
Position setup items affect how the TDD2 calculates a scaled and offset position
value from the raw position read from the sensor. The available position setup items
are listed in Table 10 and discussed in section 4.2.
Displayed As
Item Name
Manual
Section
Item Type
Possible Values
Default
Setting
UNITS
Position Units
List
Inches(
)
,
Feet (
),
Millimeters(
)
,
Centimeters(
),
Meters(
)
Inches
rESOLU
Sensor
Resolution
Floating
Point
0.00001 – 1.000 units
0.005 mm
SCALE
Position Scale
Floating
Point
0.00001 – 9.99999
1.00000
HOFFST
Hard Position
Offset
Floating
Point
-99999.99999 –
99999.99999
0.00000
SOFFST
Soft Position
Offset
Floating
Point
-99999.99999 –
99999.99999
0.00000
dSENSE
Direction Sense
List
Positive(
),
Negative(
)
Positive
dSPTYP
Display Mode
List
Single(
), Gap(
), Relative(
)
Single
AGNET
Displayed
Magnet
Integer
1 – 15
1
GAP
Displayed Gap
Integer
1 – 14
1
FALLBA
Single-Magnet
Fallback
List
No, Yes
No
REFRNC
Reference
Magnet
Integer
1-15
1
I OFF 1
through
I OFF 15
Per Magnet
Offsets
Floating
Point
-99999.99999 –
99999.99999
0.00000
Table 11: Postion Setup Items