26
5.7
Analog Output Setup Items
Analog output setup items configure the TDD2’s analog output system. The
available setup items are discussed in section 4.6.
Displayed As
Item Name
Manual
Section
Item Type
Possible Values
Default
Setting
Voltage Range
List
0 to 5V(
),
0 to 10V(
),
-5 to 5V(
),
-10 to 10V(
),
-2.5 to 2.5V(
),
-2.5 to 7V(
)
0 to 10V
Analog Source
Data
List
Forced(
),
Position(
),
Velocity(
)
Forced
Analog Start
Floating
Point
-99999.99999 –
99999.99999
0.00000
Analog Range
Floating
Point
-99999.99999 –
99999.99999
10.00000
Force Percentage
Floating
Point
0.00 – 100.00
0.00
Table 15: Analog Output Setup Items
5.8
Digital Input Setup Items
The digital input setup items are used to configure the actions performed when
the digital inputs are active. See section 4.7 for a list of the possible actions.
Displayed As
Item Name
Manual
Section
Item Type
Possible Values
Default
Setting
Input 0 Action
Integer
See Section 4.7
0
Input 1 Action
Integer
See Section 4.7
0