32
and
m
is the desired mode, “POS”, “NEG”, “ABS”
Examples:
To read the currently used peak display mode from a TDD2 with node id 1 send:
$1RKM
<CR>
To set the peak display mode to positive using a TDD2 with node id 3 send:
$3SKMPOS
<CR>
7.3.6
Clear Peak Reading
Clears the current peak reading by setting the peak reading to the current position.
Write Syntax:
$
<id
>
SKC
<CR>
where:
id is the node id of the TDD2
7.4
Position Settings
7.4.1
Units
Reads or sets the unit used for display. See section 4.2.1 for information on this setting.
Read Syntax:
$
<id>
RPU
<CR>
Write Syntax:
$
<id
>
SPU
<u><CR>
where:
id
is the node id of the TDD2
and
u
is the desired units, “INCHES”, “FEET”, “MM”, “CM”, “METERS”
Examples:
To read the currently used units from a TDD2 with node id 1 send:
$1RPU
<CR>
To set the displayed units to METERS using a TDD2 with node id 3 send:
$3SPUMETERS
<CR>
7.4.2
Resolution
Reads or sets the resolution of the sensor. See section 4.2.2 for information on this setting.
Read Syntax:
$
<id>
RPR
<CR>
Write Syntax:
$
<id
>
SPR
<r><CR>
where:
id
is the node id of the TDD2