15.4 Heat Exchanger
The heat exchanger consists of a four-pass design with 1.75" outer diameter [aluminized steel] [409
stainless steel] tube. The tube plates are made of [aluminized steel] [409 stainless steel]. The tube
supports are made of [aluminized steel] [409 stainless steel].
15.5 Louvers and Louver Spring
The louvers for standard range models UHA[T][M][X][S]150 - UHA[T][M][X][S]400 are only available in
horizontal configurations.
Description
UHA[T][M][X][S]
150 - 175
UHA[T][M][X][S]
200 - 250
UHA[T][M][X][S]
300 - 400
Horizontal Louvers P/N
11011847
11011847
11011846
Spring P/N
91901200
91901200
91901200
Quantity
7
9
11