background image

7. Operation
 

6.1.If using flexible tubing, attach the ends of the tubing to the tanks. In the 

 

absence of an appropriate slot, solidly grasp the delivery tube before beginning 

 

dispensing.

 

6.2 Before starting the pump, make sure that the delivery valve is closed 

 

(dispensing nozzle or line valve).

 

6.3.Turn the ON/OFF switch to ON. The by-pass valve allows functioning with the 

 

delivery closed only for brief periods.

 

6.4 Open the delivery valve, solidly grasping the end of the tubing.

 

6.5 Close the delivery valve to stop dispensing.

 

6.6 When dispensing is finished, turn off the pump.

 

 

ATTENTION!

 

 

Function with the delivery closed is only allowed for brief periods (2-3 

 

 

minutes maximum).

 

 

After using, make sure the pump is turned off.

8. Maintenance and trouble shooting

All models are designed and constructed to require a minimum of maintenance.
In any case always bear in mind the following basic recommendations for a good functioning of the 
pump:
 

- On a weekly basis, check that the tubing joints have not loosened, to avoid 

 

  any leakage.

 

- On a monthly basis, check the pump body and keep it clean of any impurities.

 

- On a weekly basis, check and keep clean the line suction filter.

 

- On a monthly basis, check that the electric power supply cables are in good 

    

  condition.

 Problem

Possible cause

Correct iv act ion

t he mot or is not
t urning

lack of elect rical pow er

check t he elect rical connect ion

mot or problems

cont act t he service depart ment

t he mot or t urns
slow ly w hen st art ing

low volt age in t he elect ric
pow er line

bring t he volt age back w it hin t he
ant icipat ed limit s

No.

Description

Qty.

No.

Description

Qty.

1

Mounting plate (4501.70023)

1

7

ZPA-AB/Z (# 28 283)

1

2

Mounting set pump (16 pts.)

1

7

ZPA 15 AB (# 28 275)

1

3

Clamp set (4 pts.)

1

8

Delivery hose

6,5m

4

Suction connection hose

1,5m

9

ABP 10230/1 (# 28 223)

1

5

CDS-AB (# 28 271)

1

10

Hose nipple

1

6

SEC-AB (# 28 272)

1

10

+49 (6158) 92980-0

Summary of Contents for ABS 200 A-PKW

Page 1: ...E S E N V I R O N M E N T A L L Y E F F E C T I V E S E C U R E i Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor Technical Modifications are subject to change Details techniques su...

Page 2: ...moved Always wear safety cloths respecting the applicable regulations for accident prevention Only use this device conforming to its purpose and function Improper use can cause severe injuries Caution...

Page 3: ...l value ATTENTION Power from lines with values outside the indicated limits can damage the electrical components 2 3 Working cycle The pumps are designed for continuous use under maximum back pressure...

Page 4: ...formance with EN 60034 5 86 regulations self ventilated 5 Assembling Installation 1x a1 1x a2 3x b1 1x a4 4x j 4x f 1x b2 1x b3 1x b4 1x b5 ISO 7380 M5 x 12 2x a3 1x b6 1x e 4x m 4x n 4x o DIN 912 M5...

Page 5: ...b5 b1 b4 l k b7 1 49 6158 92980 0 5...

Page 6: ...f a3 a1 a2 g h h i a4 m c1 n o p 6 49 6158 92980 0 3 2...

Page 7: ...b2 j b6 b3 5 j b6 c2 6 7 5 4 7 49 6158 92980 0...

Page 8: ...1 2 d j e c2 ABS 200 Z PKW i j 8 8 49 6158 92980 0...

Page 9: ...9 2 5 10 7 1 4 3 6 8 6 Spare parts and accessories 9 49 6158 92980 0...

Page 10: ...nance In any case always bear in mind the following basic recommendations for a good functioning of the pump On a weekly basis check that the tubing joints have not loosened to avoid any leakage On a...

Page 11: ...3 Technical modifications are subject to change without announcement 8 Maintenance and trouble shooting Problem Possible cause Correctiv action low or no ow rate low level in the suction tank rell the...

Page 12: ...Fax 49 6158 92980 50 info rapid group de Rapid Group GmbH Bahnhofstra e 53 55 64560 Riedstadt Telefon 49 6158 92980 0 www rapid group de 12 49 6158 92980 0...

Reviews: