2. Operating conditions

 

2.1 Environmental conditions

 

 

TEMPERATURE

: Min. -10°C

14°F

 / Max. +60°C(140°F)

 

 

RELATIVE HUMIDITY: 

Max. 90%

 
 

 

ATTENTION!

 

 

 THE MOTORS ARE NOT OF AN ANTI-EXPLOSIVE TYPE. 

 

 

ATTENTION!

 

 

 It is the installer’s responsibility to use tubing with adequate 

 

 

 characteristics.

 

 

ATTENTION!

 

 

 The temperature limits shown apply to the pump components 

 

 

 and must be respected to avoid possible damage or malfunction.

 

2.2 Electrical power supply

 

 

Depending on the model, the pump must be supplied by a single-phase 

 

 

alternating current line whose nominal values are shown in the table in 

 

 

Paragraph B1 – ELECTRICAL SPECIFICATIONS.

 

 

The maximum acceptable variations from the electrical parameters are:

 

 

Voltage: 

+/-5% of the nominal value

 

 

Frequency: 

+/-2% of the nominal value

 

 

ATTENTION!

 

 

Power from lines with values outside the indicated limits can damage

 

 

the electrical components.

 

2.3 Working cycle

 

 

The pumps are designed for continuous use under maximum back pressure.

 

 

ATTENTION!

 

 

Functioning under by-pass conditions is only allowed for brief periods 

 

 

of time (2-3minutes maximum).

 

2.4 Fluids permitted

 

 

• Chemical products: Urea, weak acid & weak alkaline fluid etc.

 

 

• Water

Moving and transport
Given the limited weight and size of the pumps (see overall dimensions), moving the pumps do not 
require the use of lifting devices.
The pumps were carefully packed before shipment. Check the packing material on delivery and store in 
the dry place.

3. Technical data

Dimensions (LxBxH) (mm) (barrel incl.)

652-717x240x1290

Suct ion line 

G3/4" /DN 19/1,5m

Dispensing line

G3/4" /DN 19/6,5m

Weight (kg)

10

Sound level (db) w it h 1m dist ance t o device

<80

Suct ion capacit y (l/min)

10

Volt age (V)

230 (50Hz)

Pow er input (kW)

0,12

+49 (6158) 92980-0

3

Summary of Contents for ABS 200 A-PKW

Page 1: ...E S E N V I R O N M E N T A L L Y E F F E C T I V E S E C U R E i Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor Technical Modifications are subject to change Details techniques su...

Page 2: ...moved Always wear safety cloths respecting the applicable regulations for accident prevention Only use this device conforming to its purpose and function Improper use can cause severe injuries Caution...

Page 3: ...l value ATTENTION Power from lines with values outside the indicated limits can damage the electrical components 2 3 Working cycle The pumps are designed for continuous use under maximum back pressure...

Page 4: ...formance with EN 60034 5 86 regulations self ventilated 5 Assembling Installation 1x a1 1x a2 3x b1 1x a4 4x j 4x f 1x b2 1x b3 1x b4 1x b5 ISO 7380 M5 x 12 2x a3 1x b6 1x e 4x m 4x n 4x o DIN 912 M5...

Page 5: ...b5 b1 b4 l k b7 1 49 6158 92980 0 5...

Page 6: ...f a3 a1 a2 g h h i a4 m c1 n o p 6 49 6158 92980 0 3 2...

Page 7: ...b2 j b6 b3 5 j b6 c2 6 7 5 4 7 49 6158 92980 0...

Page 8: ...1 2 d j e c2 ABS 200 Z PKW i j 8 8 49 6158 92980 0...

Page 9: ...9 2 5 10 7 1 4 3 6 8 6 Spare parts and accessories 9 49 6158 92980 0...

Page 10: ...nance In any case always bear in mind the following basic recommendations for a good functioning of the pump On a weekly basis check that the tubing joints have not loosened to avoid any leakage On a...

Page 11: ...3 Technical modifications are subject to change without announcement 8 Maintenance and trouble shooting Problem Possible cause Correctiv action low or no ow rate low level in the suction tank rell the...

Page 12: ...Fax 49 6158 92980 50 info rapid group de Rapid Group GmbH Bahnhofstra e 53 55 64560 Riedstadt Telefon 49 6158 92980 0 www rapid group de 12 49 6158 92980 0...

Reviews: