Refer to troubleshooting spreadsheet below. Solutions in yellow may be performed by customer without need to return machine.
No.
Normal Operation
Problem
Warning
Sound
Cause
What to Check
Solution
1
Power on → Tip Axis is
initialized and the wire-
cutter operates
automatically.
No operation
takes place.
No sound
emitted.
Battery completely empty.
Confirm the battery is charged.
Perform normal charge.
Electrode plate has been
oxidized.
Take out the battery and see if
the electrode has gone brown.
Polish terminal part of battery
pack with clean cloth, etc.
Continuous
short beeps
Curl guide is open.
Open/close curl guide.
Fully close curl guide.
Tie wire is tangled on the
twister.
Check the twister for tangled
wire.
Remove tangled wire from the
twister.
Two long
beeps
repeated
Battery is empty.
Confirm the battery is charged.
Perform normal charge.
Tip Axis
Initializing fails
Seven short
beeps
repeated
There is foreign substance
between Magnetic plate (#61)
and Route PWB unit (#62) or
bad connection of connecting
wire K.
Check if there is foreign
substance between Magnetic
plate (#61) and Route PWB
unit (#62) or check the wire K
connection.
Remove the foreign substance
between Magnetic plate (#61)
and Route PWB unit (#62) or
replace with new connecting
wire K.
Four short
beeps
repeated
Bad connection of connecting
wire A and B or twisting motor
is burned.
Check the wire A and B
connection.
Reconnect or replace the wire A
and B or replace with new
twisting motor.
2
Trigger ON → Wire is
sent out.
No wire is sent
out.
Continuous
short beeps
Curl guide is open.
Open/close curl guide.
Fully close curl guide.