INTRODUCTION

The Lectra/San and ElectroScan do not require a salt 

feed system when operating in ocean water with a 

salt content of 3.5%.  A salt feed system needs to be 

utilized if operating in fresh or brackish water.  This 

system can be used with all Lectra/San or ElectroScan 

models.  Low salt is indicated on the unit’s Control 

Indicator Panel.  Salt can be added to the Lectra/San 

using a Four Gallon Salt Feed Tank.  For dimensions 

see Fig. #1.  

Additional parts included:  

Strapping for the tank.  

Additional parts required: 

 Mounting hardware, 

shutoff  valve,  plumbing  fittings,  1/2”  (12.7  mm) 

hose for pressurized freshwater and 1/2” (12.7 mm) 

hose for overflow.

Pressurized freshwater is required.  Minimum of 15 

psi (103 kPa) working pressure. 

OPERATION

Solar Salt is added directly to the tank (see refill

-

ing salt in the system).  Water supplied by the boats 

pressurized freshwater maintains the water level 

in the tank and continues to make a saturated salt 

solution from the solar salt.  Every time the toilet is 

flushed, a portion of the salt water solution is mixed 

with incoming water to increase water salinity in the 

Treatment Tank.  A Low Salt indication on the unit’s 

Control Indicator Panel will indicate time to refill 

tank with more salt.
The amount of saturated salt solution entering the 

Treatment Tank can be decreased or increased by 

adjusting the plastic tubing clamp (#31-304C).  To 

FOUR GALLON SALT FEED SYSTEM (Part #31-3005)

Installation and Maintenance Instructions

decrease the amount of salt solution entering system, 

adjust plastic tubing clamp to pinch tubing restricting 

flow.  To increase the amount of salt solution, release 

plastic  tubing  clamp  to  remove  restriction.    (See 

Start Up section for more details).  When operating 

in proper salinity, close the plastic tubing clamp to 

avoid unnecessary drain of salt solution from the tank.  

Reopen plastic tubing clamp when needed. 

Refilling salt in the system:

  Add up to 20 lbs. (9kg) 

of solar salt directly into tank.  Some water may be 

displaced through overflow tube.  The water level 

will drop back to its normal level after a few uses. 

NOTE:  Before refilling tank with solar salt, check 

the filter screen (#31-313) and make sure it is clean 

(see Fig. #2).

 

    THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED  

    

 

 

         DURING BOTH INSTALLATION AND OPERATION

 

WARNING:

 Raritan Engineering Company, Inc. recommends that a qualified person or technician install this 

product.  Equipment damage, injury to personnel or death could result from improper installation.  

Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment, or 

injury or death to personnel, that may result from improper installation or operation of this product.

10 1/2"

(27cm)

16"

(41cm)

Fig. #1  Four Gallon Salt Feed System Dimensions 

and Mounting

L288B   0917jlc                                                                                                         

Summary of Contents for 31-3005

Page 1: ...reatment Tank can be decreased or increased by adjusting the plastic tubing clamp 31 304C To FOUR GALLON SALT FEED SYSTEM Part 31 3005 Installation and Maintenance Instructions decrease the amount of salt solution entering system adjustplastictubingclamptopinchtubingrestricting flow To increase the amount of salt solution release plastic tubing clamp to remove restriction See Start Up section for ...

Page 2: ...mbers refer to toilet parts and not in the T Check valve When connecting to a PHII remove 1201 and LWS for Crown Heads remove CH12 and CH8 for CrownHeadIIandAtlantesmodelsreplace RCV with T Check valve provided Other types of toilets need not be modified unless they have an additional built in check valve 7 Install overflow hose to bilge 8 Connect pressurized freshwater with a shutoff valve to the...

Page 3: ...oubleshooting if low salt indication continues With no low salt indication start closing plastic tubing clamp until low salt indication comes on and open plastic tubing clamp slightly again for optimum salt without low salt indication Flush toilet four times between each adjustment Fig 3 Raritan s PHII Manual Toilet Shown with Four Gallon Salt Feed System Fig 4 Electric Toilet with remote intake p...

Page 4: ...efects caused by installation of this product other than in accordance with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANYEXPRESSWARRANTYNOTPROVIDED HEREIN ANDANYREMEDYFOR BREACH OF C...