Chapter 15: Advanced Administration
252
3. Select a Device Type in the table and double-click the Default Port
value.
4. Type the new Default Port value.
5. Click Update Configuration to save your changes.
To configure timeout duration for devices:
1. Choose Administration > Configuration.
2. Click the Device Settings tab.
3. Type a new timeout duration in the Heartbeat (sec) field. The valid
range is 30 seconds to 50,000 seconds.
4. Click Update Configuration to save your changes.
To enable or disable a warning message for all power
operations:
Select the Display Warning Message For All Power Operations checkbox
to enable a warning message that alerts a user before a requested
power operation occurs. Only the user who initiated the power operation
sees the message. The user can cancel the power operation or confirm it
by clicking Yes or No in the message.
1. Choose Administration > Configuration.
2. Click the Device Settings tab.
3. Select the Display Warning Message For All Power Operations
checkbox to enable the warning message. Deselect the checkbox to
disable the warning message.
4. Click Update Configuration to save your changes.