Appendix A: Specifications
285
SuSE 11
pcsc-lite-1.4.102-1.24
Fedora
®
Core 10
pcsc-lite-1.4.102.3.fc10.i386
Create a Java
™
Library Link
A soft link must be created to the libpcsclite.so after upgrading RHEL
4, RHEL 5 and FC 10. For example, ln
–s /usr/lib/libpcsclite.so.1
/usr/lib/libpcsclite.so, assuming installing the package places the
libraries in /usr/lib or /user/local/lib.
PC/SC Daemon
When the pcsc daemon (resource manager in framework) is
restarted, restart the browser and MPC, too.
Environmental Requirements
Operating
Temperature
0°C- 40°C (32°F - 104°F)
Humidity
20% - 85% RH
Altitude
N/A
Vibration
5-55-5 HZ, 0.38mm, 1 minutes per cycle;
30 minutes for each axis (X, Y, Z)
Shock
N/A
Non-Operating
Temperature
0°C- 50°C (32°F - 122°F)
Humidity
10% - 90% RH
Altitude
N/A
Vibration
5-55-5 HZ, 0.38mm, 1 minutes per cycle;
30 minutes for each axis (X, Y, Z)
Shock
N/A
Emergency Connectivity
Connection
Description
Optional modem
connectivity
For emergency remote access if the network
has failed.
Target device
connectivity
Simplified RJ45-based CAT 5 cable scheme;
serial port adapters are available from Raritan.