background image

WINTERIZING

Winterizing:

Improper winter lay up is a major cause of marine
toilet failure.

Use only nontoxic antifreeze.

Flush toilet several times to clear waste from
system.

Dispose of all antifreeze in accordance with local
and federal regulations.

Winterize holding tanks, plumbing, treatment
systems (MSD’s), etc. independently following
manufacturer’s instructions.

Pressurized Freshwater Models

Parts Required

1" (25 mm.) or 1 1/2" (38 mm.) I.D.
discharge hose, approximately 3 feet (1 m.) long

Two buckets

Nontoxic antifreeze approximately 1 quart

(1 liter)

Steps

1. Close discharge seacock (if one exists).

2. Shut off intake water at source.

3. Turn off power to unit.

4. Disconnect and drain discharge hose.

5. Disconnect intake hoses from water solenoid  and

place in one of the buckets.

6. Connect short hose to toilet’s discharge and place

in other bucket.

7. Pour antifreeze in bowl.

8. Turn on power to unit and flush until antifreeze is

removed from the bowl and water is drained from
the solenoid and hose.

9. Disconnect power to toilet.
10. Reconnect intake hoses to water solenoid

Integral and Remote Intake Pump Models

Parts Required

3/4" (19 mm.) I.D. intake hose approximately 3 feet

(1 m.) long.

1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge hose
approximately 3 feet (1 m.) long.
Two buckets

Nontoxic antifreeze approximately 1 quart (1 liter)

Steps

1. Close the intake and discharge seacocks.

2. Turn off power to unit.
3. Disconnect and drain intake hose and discharge

hose .

4. Connect short  hoses to toilet’s intake and discharge.

5. Place one bucket under hose connected to toilet’s

discharge.

6. Pour nontoxic antifreeze in other bucket.
7. Place hose connected to intake pump into bucket

with antifreeze.

8. Turn on power to unit and flush toilet until

antifreeze begins to be discharged from toilet.

9. Disconnect power from toilet.

RECOMMISSIONING

1. Using the buckets, hoses and approximately one

gallon (3.8 liters) of clean fresh water, flush
antifreeze out of the toilet (see Winterizing).
Dispose of antifreeze in accordance with local
and federal regulations.

2. Reconnect the intake and discharge hoses and

open both seacocks and water source valve.

3. Check all connections for leaks with several test

flushes.

SYSTEM START-UP

1. Open seacock(s).

NOTE:  Pressurized freshwater models; open water
source valve.

2. Turn on power to toilet.

3. Flush toilet per Operation Instructions.

4. Check for leaks.

IMPORTANT:  If toilet does not flush properly
or if water does not enter the bowl within 10
seconds, refer to Troubleshooting.

5

Summary of Contents for Elegance

Page 1: ...gonlytheabilityto flushwithnoindependantcontrolofwateror Marine Elegance Elegance Elegance Elegance Elegance THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLA...

Page 2: ...pinstalled between the intake pump and the toilet bowl Doubleclampallbelowwaterlineconnections Recommended Visual Inspection 3 3 3 3 3 For leaks at toilet and hose connections 3 3 3 3 3 Hoseclamps 3 3...

Page 3: ...to evacuatethebowl Dischargepumprunsas longasthisbuttonisheld 2 Water Only Press Water Only switch to addwaterinthebowl Inletwatersolenoid pumprunsaslongasbuttonispressedwith asevensecondslimit After...

Page 4: ...retention fill Time After placing the unit in program mode Step 1 above push the WATER ONLY button the number of times required for the Water Valve Inlet Pump time one push ZERO sec s two 1 sec three...

Page 5: ...et 1m long 1 25 mm or 1 1 2 38 mm I D discharge hose approximately3feet 1m long Two buckets Nontoxicantifreezeapproximately1quart 1liter Steps 1 Close the intake and discharge seacocks 2 Turnoffpowert...

Page 6: ...2 p o r d e g a t l o v 3 r o f 4 5 0 1 n o d e s a b e r a s e z i s r o t c u d n o c d e d n e m m o c e R o n o i t a l u s n i d e t a r C s g n i t a r n o i t a l u s n i r e h t o r o f s d r...

Page 7: ...dist 7 8 Hence a maximum of 7 high loop can be installed 6 4 2 0 20 40 60 80 100 0 120 140 160 180 Horizontal distance Feet Marine Elegance discharge Maximum recommended 1 PVC hose length Parts inclu...

Page 8: ...ket assembly to deck using 14 self threading bolts and flat washers Note place bolts as close to mark linesA B and C as possible 5 Drill holes for discharge 1 5 8 41 mm inlet hose 7 8 22mm andwires 3...

Page 9: ...lampallbelow waterlineconnections IMPORTANT Fittings and 90 bends should be kept to a minimum In Line Strainer may be installed on Sea Water Models per Installation Instructions This will prevent clog...

Page 10: ...ed 1 Slidefittingclipstoopenposition 2 Select inlet port to be used 3 Installappropriatefittingsintoinletandoutletports NOTE The 90 fitting can be rotated 360 4 Installtheplugfittingintounusedinletpor...

Page 11: ...g holesusingwallplateasguide 2 Route wire to the toilet and control 3 Securecontrolwithgasketusingtwo screws C Smart Flush Control 1 Cut out a hole per Fig 13 mark mounting holesusingwallplateasguide...

Page 12: ...power source for remote pump to remote pump and back Same wire gauge mustbeusedforbothlowerbaseandremote pump 2 Select proper wire and fuse circuit breaker size fromSpecificationsonInstallationpage 3...

Page 13: ...noid valve Discharge pump Fig 14 Wiring for Push Button Switch Fresh water model To EST Discharge pump Black RED Blue Blue Black RED Fuse Pump Relay RED Push Button Push Button BATTERY 13 Fig 14A Wiri...

Page 14: ...L PANEL FUSE BREAKER orange black red black red black panel tankfullswitch ESTinput BATT FLUSH CONTROL PANEL FUSE BREAKER Relay PUMP remote Fig 15 WIRINGFOR SMART SWITCH FRESHWATER MODEL Fig 16 WIRING...

Page 15: ...Breaker red orange black blue black red RED Relay Fig 18 WIRING FOR ME TOILET CONTROL WITH REMOTE PUMP Fig 17 WIRINGFOR ME TOILET CONTROL FRESHWATER MODEL Solenoid Valve Discharge Pump Discharge Pump...

Page 16: ...necthosesandwireplugs see Fig 19 Caution Do not pull on the discharge hose to avoid kinking 8 Installmountingbushings bolts SeeFig 20 9 Tightenboltsbeingcarefultonotovertighten Do notexceed30inchlb wh...

Page 17: ...chargeline 4A Pressurebuildupatseacocks 5A LeakingBowlThroatadapter 5B Leakatshaftseal 5C Leak from bowl spud SOLUTION 1A Besuredischargeseacockisopen Clearline remove clog 1B Replumbtoeliminatebendsa...

Page 18: ...F195 Front mounting washer 1 F196 Front mounting snap cap 1 M23A Lockwasher 166000 Remote pump complete 12v 166100 Remote pump complete 24V 1660 Motor raw water pump 161115 Impeller 161123 Macerator...

Page 19: ...5 162225 162135 162100W 162420 162200W 190601 Recommended EXPLODED PARTS F193 freshwater strainer Recommended Seawater strainer 19 FIG 21 221100 F186VT 221210 221110 221150 221300 161123 161115 31 102...

Page 20: ...psupplied byothersintheprocessofinstallationofthisproduct defectscausedbyinstallationofthisproduct otherthaninaccordancewiththemanufacturer srecommendedinstallationinstructionsorstandard industryproce...

Reviews: