Event/Context
Default Assertion Message when
the Event = TRUE
Default Assertion Message
when the Event = FALSE*
Peripheral Device Slot > * >
Numeric Sensor > Above upper
critical threshold
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' asserted 'above
upper critical' at [READING].
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' deasserted
'above upper critical' at
[READING].
Peripheral Device Slot > * >
Numeric Sensor > Above upper
warning threshold
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' asserted 'above
upper warning' at [READING].
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' deasserted
'above upper warning' at
[READING].
Peripheral Device Slot > * >
Numeric Sensor > Below lower
warning threshold
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' asserted 'below
lower warning' at [READING].
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' deasserted
'below lower warning' at
[READING].
Peripheral Device Slot > * >
Numeric Sensor > Below lower
critical threshold
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' asserted 'below
lower critical' at [READING].
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' deasserted
'below lower critical' at
[READING].
Peripheral Device Slot > * >
State Sensor > Unavailable
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' unavailable.
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' available.
Peripheral Device Slot > * >
State Sensor > Alarmed / Open
/ On
Peripheral device
'[EXTSENSORNAME]' in slot
[EXTSENSORSLOT] is
[SENSORSTATENAME].
Peripheral device
'[EXTSENSORNAME]' in slot
[EXTSENSORSLOT] is
[SENSORSTATENAME].
Inlet > * > Enabled
Inlet '[INLET]' has been enabled by
user '[USERNAME]' from host
'[USERIP]'.
Inlet '[INLET]' has been disabled
by user '[USERNAME]' from host
'[USERIP]'.
Inlet > * > Sensor > * >
Unavailable
Sensor '[INLETSENSOR]' on inlet
'[INLET]' unavailable.
Sensor '[INLETSENSOR]' on inlet
'[INLET]' available.
Inlet > * > Sensor > * > Above
upper critical threshold
Sensor '[INLETSENSOR]' on inlet
'[INLET]' asserted 'above upper
critical'.
Sensor '[INLETSENSOR]' on inlet
'[INLET]' deasserted 'above upper
critical'.
Inlet > * > Sensor > * > Above
upper warning threshold
Sensor '[INLETSENSOR]' on inlet
'[INLET]' asserted 'above upper
warning'.
Sensor '[INLETSENSOR]' on inlet
'[INLET]' deasserted 'above upper
warning'.
Inlet > * > Sensor > * > Below
lower warning threshold
Sensor '[INLETSENSOR]' on inlet
'[INLET]' asserted 'below lower
warning'.
Sensor '[INLETSENSOR]' on inlet
'[INLET]' deasserted 'below lower
warning'.
Inlet > * > Sensor > * > Below
Sensor '[INLETSENSOR]' on inlet
Sensor '[INLETSENSOR]' on inlet
Summary of Contents for PX3-4000 series
Page 5: ......
Page 627: ...Appendix I RADIUS Configuration Illustration 606 Note If your PX uses PAP then select PAP...
Page 632: ...Appendix I RADIUS Configuration Illustration 611 14 The new attribute is added Click OK...
Page 633: ...Appendix I RADIUS Configuration Illustration 612 15 Click Next to continue...
Page 648: ...Appendix J Integration 627 3 Click OK...
Page 661: ...Appendix J Integration 640 2 Launch dcTrack to import the spreadsheet file...