Appendix F: Additional PXE Information
352
"To Assert" and Assertion Timeout
If multiple sensor states are available for a specific sensor, the PXE
asserts a state for it whenever a bad state change occurs.
Assert a state:
To assert a state is to announce a "worse" new state. Below are bad
state changes that cause the PXE to assert.
1. above upper warning --> above upper critical
2. normal --> above upper warning
3. normal --> below lower warning
4. below lower warning --> below lower critical
Assertion Timeout:
In the threshold setup dialog, the Assertion Timeout field impacts the
"assert" action. It determines how long a sensor must be in the "worse"
new state before the PXE turns on the "assert" action. If that sensor
changes its state again within the specified wait time, the PXE does NOT
assert that state.
To disable the assertion timeout, set it to 0 (zero).