Select <Auto Mode> with UP or DOWN and press ENTER to confirm. 

Set the master unit to work in one of the running modes. 

Connect the master unit as the first unit in the chain by connecting the DMX output of the 

master device to the DMX input of the first slave unit. 

12

Rasha Professional A/S | 1800 Rustin Ave, Riverside, CA, 92507 | 951-654-3585 

Rashaprofessional.com | info@rashaprofessional.com

Use DMX Signal Cable connect the controller boxes.

5.8. DMX Mode

Attention

The DMX mode allows you to control the device with any universal DMX controller.

All DMX-controlled devices need a digital start address so that the correct device responds 
to the signals. This digital start address is the channel number from which the device 

starts to “listen” to the DMX controller. The same starting address can be used for a whole 

group of devices or an individual address can be set for every device.

When all devices have the same address, all the units will “listen” to the control signal on 

one particular channel. In other words: changing the settings of one channel will affect all 

devices simultaneously. If you set individual addresses, each device will “listen” to a 

separate channel number. Changing the settings of one channel will only affect the device 
in question.

Start Addresses

After switching on, the device will automatically detect whether DMX 512 data is received or
not. If there is data received at the DMX input, the DMX LED next to the LCD display will flash.
If no DMX signal data is received? This situation can occur if:

the XLR plug (cable with DMX signal from controller) is not connected with the input of
the device.

the controller is switched off or defective, if the cable or connector is defective or the
signal wires are swap in the input connector.

To set the device to work with a DMX controller

* Press MODE until <DMX Address> is displayed and press ENTER.
* Use <UP> and <DOWN> to set the DMX start address and press ENTER.

Use the table below to define the correct address. The table shows the settings for units 1 to 
3. Apply the same principle for the other units. Example:

Channel Mode 

First Unit 

Second Unit 

Third Unit 

Highest Start address

8

Start Address 

1

9(1+8)

17(9+8)

505

Summary of Contents for Cosmos

Page 1: ...QUICK USER MANUAL RASHA PROFESSIONAL A S Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 Rashaprofessional com info rashaprofessional com 1 Fiesta Cosmos ...

Page 2: ...2 Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 Rashaprofessional com info rashaprofessional com How to turn the controller line from 3 pins into 5 pins plug and sockets ...

Page 3: ... manual thoroughly before bringing this device into service If the device was damaged in transit don t install or use it and contact your dealer 2 Safety Instructions Keep this device away from children and unauthorized users Controller Box Indoor use only Keep this device controller away from rain moisture splashing and dripping liquids Never put objects filled with liquids on top of or close to ...

Page 4: ...r the creation of scenography set with dynamic and graphic contents One set exists of 1 controller with 4 outputs and total 8 string 15 meter 49 2 with 20 ball each string Each output on the controller can be 30 meter 98 42 2 string of 15 meter 49 2 with 20 balls One controller can control total of 120 meter 393 701 with 160 balls in total Each individually controlled in pixel to pixel Power and c...

Page 5: ...indicates the product s average current draw under normal conditions Always connect the product to a protected circuit circuit breaker or fuse Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging ...

Page 6: ... distance to the controller and other strings Use the ball tension string if necessary Make sure that the structure onto which you are mounting the product can support the product s weight See the Technical Specifications for weight information Use the built in eyelets to hang the Fiesta String and BALLs The ball tension string may be hung with zip ties or equivalent Installed fuse held by plastic...

Page 7: ...s are used as end or corner supports they will need to be tied back The height of the attachment point should be at least 8 feet 2 4 meter or higher when deemed necessary 7 Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 Rashaprofessional com info rashaprofessional com Mounting Diagram Pixel Controller Cosmos Rear Keyhole Mounting Use a level to ensure accuracy while mountin...

Page 8: ...os control box is required Cosmos Sold separately Cosmos its compatible with our multiple pixel products Fiesta Ball 1 string its 15 Meter 49 21 feet with 20 bulbs each bulb has 6 leds RGBW 1 Cosmos can control 160 pcs ball or 8 Strings Rasha Fiesta bulb must hang at a 90 degree perpendicular angle to maintain an IP65 rating This end goes to additional Fiesta Strings Fiesta BALL If you are not usi...

Page 9: ...sional com 5 3 Control Panel Button Function Menu Access the menu Return to a previous menu option Enter Select menu option Store the current menu or option within the menu Up Scroll through the menu options in ascending order Increase Value Down Scroll through the menu options in descending order Decrease value ...

Page 10: ...p OutPut 1 OutPut 2 OutPut 4 255 255 255 YES NO LED CONTROL 2 4 001 512 Operation Mode Signal Lost Auto Mode Network Settings Ball Tube Port Mode R G B System Reset Software Version DMX Address 002 000 000 002 000 00 08 255 000 000 000 1 9 1 19 Mix Menu R G B 10 Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 Rashaprofessional com info rashaprofessional com Menu Refer to the...

Page 11: ...o confirm Select an option with UP or DOWN and press ENTER to confirm Select SPEED with UP or DOWN and press ENTER to confirm Select a speed with UP or DOWN and press ENTER to confirm 5 7 Slave Mode Notes The Slave mode allows for connecting several devices to a single master device in a daisy chain All slave devices will then work synchronously with the master device Configure all slave units bef...

Page 12: ...ar channel In other words changing the settings of one channel will affect all devices simultaneously If you set individual addresses each device will listen to a separate channel number Changing the settings of one channel will only affect the device in question Start Addresses After switching on the device will automatically detect whether DMX 512 data is received or not If there is data receive...

Page 13: ...P27 Program 12 208 223 P28 Program 13 224 239 P29 Program 14 240 255 CH8 000 255 P14 Program 14 P15 Program 15 Increasing speed of the program settings under Channels 6 and 7 Functions Green 0 100 Blue 0 100 Dimmer 0 100 Strobe increasing speed 0 100 Red 0 100 No function P3 Program 3 P4 Program 4 P5 Program 5 P6 Program 6 No Function P1 Program 1 P2 Program 2 CH6 CH7 P mix Programs 1 29 in an end...

Page 14: ...sion 4 TCP IPv4 network Settings 5 9 Networking Setting Art Net Mode Kling Net Mode 1 For IP segment 002 0 0 1 002 0 0 255 for example a computer can be set to the address 002 0 0 X X you can set as 99 can also be the value of the other as long as don t setting the same with controller box 2 Subnet mask can be 255 255 255 0 also can be set into 255 0 0 0 or 255 255 0 0 Gateway and must be consiste...

Page 15: ... conflict Numerical range for the standard IP address range namely 0 255 Changes SubNet Mask Subnet mask can be 255 255 255 0 also can be set into 255 0 0 0 or 255 255 0 0 Gateway and must be consistent and DNS the first three Numbers also must agree and IP Net SubNet Universal Can be used to change for the domain and the range is 000 00 00 to 000 16 16 According to the way we put device controlle...

Page 16: ...t use alcohol or solvents Do not immerse the device in any liquid There are no user serviceable parts Contact your dealer for spare parts if necessary 7 Technical Specifications Please Note All information is subject to change without prior notice Please contact to your reseller for further questions Light Source 15 Meter 49 22 string with 20x Balls RGBW Injection molding bulb do not need to make ...

Reviews: