background image

Rasha Professional A/S 1800 Rustin Ave., Riverside CA, 92507 

951-654-3585

rashaprofessional .com 

|

|

 info@rashaprofessional.com

2

Edition Notes 

The 

K2

 

, User Manual Rev. 1 covers the description, 

safety precautions, installation, programming, operation, 

and maintenance of the 

K2

. Rasha released this edition of 

the 

K2

 User Manual in July 2022.

Trademarks

Rasha

®

 Is a registered trademark of RASHA 

PROFESSIONAL A/S. (D/b/a RASHA

®

 or Rasha). The 

RASHA® logo in its entirety including the RASHA

®

 name 

and the Globe with Rings, and all other trademarks in this 

manual pertaining to services, products, or marketing 

statements are owned or licensed by RASHA

®

. Any other 

product names, logos, brands, company names, and other 

trademarks featured or referred to within this document 

are the property of their respective trademark holders.

Copyright 

Notice

RASHA owns the content of this User Manual 

in its entirety, including but not limited to 

pictures, logos, trademarks, and resources. 

© Copyright 2015 RASHA. All rights reserved. 

Electronically published by Rasha in the United States of 

America.

Manual Use

Rasha authorizes its customers to download and print this 

manual for professional information purposes only. Rasha 

expressly prohibits the usage, copy, storage, distribution, 

modification, or printing of this manual or its content for 

any other purpose without written consent from Rasha.

Document 

Printing

For better results, print this document in color, on letter 

size paper (8.5 x 11 in), double-sided. If using A4 paper 

(210 x 297 mm), configure your printer to scale the content 

accordingly.

Intended 

Audience

Any person in charge of installing, operating, and/or 

maintaining this product should completely read through 

the guide that shipped with the product, as well as this 

manual, before installing, operating, or maintaining this 

product.

Document 

Revision 

The 

K2

 User Manual Rev. 1 supersedes all previous 

versions of this manual. Discard any older versions of 

this manual and replace with this version. Go to www.

rashaprofessional.com for the latest version.

Author

Date

Editor

Date

Deepak T.

27/06/2022

Summary of Contents for K2

Page 1: ...RASHA PROFESSIONAL A S Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 rashaprofessional com info rashaprofessional com 1 QUICK USER MANUAL K2...

Page 2: ...rks and resources Copyright 2015 RASHA All rights reserved Electronically published by Rasha in the United States of America Manual Use Rasha authorizes its customers to download and print this manual...

Page 3: ...s 5 Personal Safety 5 Mounting And Rigging 5 Power And Wiring 5 Operation 5 2 Introduction 6 Description 6 Features 6 Overview 6 Dimensions 7 3 Setup 8 Power Supply 7 AC Plug 8 Fuse Replacement 8 Powe...

Page 4: ...er immediately may Void your claim In addition keep the box and contents for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a c...

Page 5: ...the surrounding environment before connecting it to power Mount this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Make sure there are no flammable mater...

Page 6: ...h and parallel beam luminaire for small to big event production venues arenas TV studio Fitted with 19 LED emitters K2 delivers luminous flow of over 10000 lumen over powering conventional luminaire K...

Page 7: ...Rasha Professional A S 1800 Rustin Ave Riverside CA 92507 951 654 3585 rashaprofessional com info rashaprofessional com 7 DIMENSIONS...

Page 8: ...utrik powerCON A connector on one end and an Edison plug on the other end U S Market If the power input cord that came with your product has no plug or if you need to change the Edison plug use the ta...

Page 9: ...affect the product If hanging this product make sure that the mounting location can support the product s weight See the Technical Specifications for the weight bearing requirements of this product Wh...

Page 10: ...Show 3 Selects and sets Preset light show mode 3 Fixture must be master Show 4 Selects and sets Preset light show mode 4 Fixture must be master Slave Mode Slave 1 Selects and save fixture on Slave Mo...

Page 11: ...and sets Dimmer frequency to 2400K 4000K Selects and sets Dimmer frequency to 4000K 6000K Selects and sets Dimmer frequency to 6000K Fan Speed Auto Selects and sets auto fan speed Slow Selects and set...

Page 12: ...5 pin XLR cable to link the unit and the DMX controller DMX512 link use 3 5 pin XLR cable to link the next unit and output DMX signal PowerCon connection from main power supply 3 Button 7 Mains OUT Po...

Page 13: ...ut Open 80 89 Moving Blackout Off 90 99 Pan Invert Open 100 109 Tilt Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL 200 209 Al...

Page 14: ...ed full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue full White 0 216 246 Red down Green 0 Blue full White 0 247 Blue Red 0 Green 0 Blue full White...

Page 15: ...ckout Open 80 89 Moving Blackout Off 90 99 Pan Invert Open 100 109 Tilt Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL 200 209...

Page 16: ...ue 0 White 0 136 174 Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue full White 0 216 246 Red down...

Page 17: ...ving Blackout Open 80 89 Moving Blackout Off 90 99 Pan Invert Open 100 109 Tilt Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan Tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL...

Page 18: ...l Blue 0 White 0 135 Yellow Red full Green full Blue 0 White 0 136 174 Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta R...

Page 19: ...Invert Open 110 119 Pan Tilt Invert Off 120 139 NULL 140 149 Pan Tilt Reset 150 179 NULL 180 189 Zoom Reset 190 199 NULL 200 209 All Reset 210 255 NULL 7CH Zoom 000 255 8CH Zoom Fine 000 255 9CH Shut...

Page 20: ...Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue full White 0 216 246 Red down Green 0 Blue full Wh...

Page 21: ...180 189 Zoom Reset 190 199 NULL 200 209 All Reset 210 255 NULL 7CH Red1 000 255 8CH Red Fine 1 000 255 9CH Green1 000 255 10CH Green Fine 1 000 255 11CH Blue1 000 255 12CH Blue Fine 1 000 255 13CH Wh...

Page 22: ...Yellow Red full Green full Blue 0 White 0 136 174 Red full Green down Blue 0 White 0 175 Red Red full Green 0 Blue 0 White 0 176 214 Red full Green 0 Blue up White 0 215 Magenta Red full Green 0 Blue...

Page 23: ...mber before shipping the product Be prepared to provide the model number serial number and a brief description of the Claim s for the return Clearly label the package with an RMA number Rasha will ref...

Page 24: ...t com UNITED STATES Rasha Professional A S LLC General Information Address 1800 Rustin Ave Riverside CA 92507 Technical Support Email support rashaprofessional com Voice 1 951 394 8480 1 951 654 3585...