background image

 

Panta-V7 Wireless Profile                                                                    Safety Precautions

•  To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture 
•  Do not spill water or other liquids into or on to your unit. 
•  Do not attempt to operate this unit if the power cord has been frayed or broken. Do not 

attempt to remove or break off the ground prong from the electrical cord. This prong is used 
to reduce the risk of electrical shock and fire in case of an internal short. 

•  Disconnect from main power before making any type of connection. 
•  Do not remove the cover under any conditions. There are no user serviceable parts inside. 
•  Never operate this unit when it

s cover is removed. 

•  Never plug this unit in to a dimmer pack 
•  Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6

 

(15cm) between this device and a wall. 
•  Do not attempt to operate this unit, if it becomes damaged. 
•  This unit is intended for indoor use only, use of this product out` doors voids all warranties. 
•  During long periods of non-use, disconnect the unit

s main power. 

•  Always mount this unit in safe and stable matter. 
•  Power-supply cords should be routed so that they are not likely to be walked on or pinched 
by items placed upon or against them, paying particular attention to the point they exit from 
the unit.   
•  Cleaning -The fixture should be cleaned only as recommended by the manufacturer.   
•  Heat -The appliance should be situated away from heat sources such as radiators, heat 
registers, stoves, or other appliances (including amplifiers) that produce heat. 
•  The fixture should be serviced by qualified service personnel when:   
A. The power-supply cord or the plug has been damaged.   
B. Objects have fallen, or liquid has been spilled into the appliance.   
C. The appliance has been exposed to rain or water.   
D.  The  appliance  does  not  appear  to  operate  normally  or  exhibits  a  marked  change  in 
performance.   
 
 
 

Panta-V7 Wireless Profile                                                                                          Set Up

 

P

ower Supply: 

The  Rasha  Tint  Wireless  Profile  contains  switching  (multi  Voltage)  voltage 

switch, which will auto sense the voltage when it is plugged into the power source. With this 
switch there is no need to worry about the correct power voltage; this unit can be plugged in 
anywhere. Light can recharge and use at same time.   

DMX-512: 

DMX  is  short  for  Digital  Multiplex.  This  is  a  universal  protocol  used  as  a  form  of 

communication  between  intelligent  fixtures  and  controllers.  A  wireless  transmitter/  DMX 
controller sends DMX data instructions from the controller to the fixture. DMX data is sent as 
serial  data  that  travels  from  fixture  to  fixture  via  the  wireless  DMX  receiver/DATA 

IN

  and 

DATA 

OUT

 XLR terminals located on all DMX fixtures (most controllers only have a DATA 

OUT

 terminal).   

DMX Linking: 

DMX is a language allowing all makes and models of different manufactures to 

be linked together and operate from a single controller, as long as all fixtures and the controller 
are  DMX  compliant.  To  ensure  proper  DMX  data  transmission,  when  using  several  DMX 
fixtures try to use the shortest cable path possible or connect wireless transmission. The order 
in  which  fixtures  are  connected  in  a  DMX  line  does  not  influence  the  DMX  addressing.  For 
example; a fixture assigned a DMX address of Addr-A001 may be placed anywhere in a DMX 
line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX 
address of A001, the DMX controller knows to send DATA assigned to address A001 to that 
unit, no matter where it is located in the DMX chain/Controller. 

Data Cable (DMX Cable) Requirements (For DMX Operation): 

The  Panta-V7  Wireless 

Profile  can  be  controlled  via  DMX-512  protocol/Wireless  DMX  transmitter.  The  Panta-V7 
Wireless Profile has 5/9 DMX channel modes,. The DMX address is set on the back panel of 
the Panta Wireless Profile. Your unit and your DMX controller require a standard 3-pin XLR 
connector/wireless  DMX  Transmitter  for  data  input  and  data  output.  We  recommend 
Rasha-Cable DMX cables/Wireless Transmitter. If you are making your own cables, be sure to 
use  standard  110-120  Ohm  shielded  cable  (This  cable  may  be  purchased  at  almost  all  pro 
lighting stores) or 2.4Mhz Wireless Transmitter/Receiver. Your cables should be made with a 
male and female XLR connector on either end of the cable. Also, remember that DMX cable 
must be daisy chained and cannot be split. 

 

Summary of Contents for PRO LIGHT PANTA-V7

Page 1: ...R P RGBAW 5 PANTA WI User 5 IN 1 A V7 IRELESS P Instruction COLORS PROFILE ns S...

Page 2: ...pped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any dam...

Page 3: ...gged into the power source With this switch there is no need to worry about the correct power voltage this unit can be plugged in anywhere Light can recharge and use at same time DMX 512 DMX is short...

Page 4: ...ll decrease the possibilities of erratic behavior 5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA transmission in place of 3 pin 5 pin DMX fixtures may be implemented...

Page 5: ...the 9Channel DMX Mode 4 Please see below pages for DMX values and traits 5 After you have chosen your desired DMX Channel mode plug in the fixture via the XLR connections to any standard DMX controll...

Page 6: ...c color or sound mode please be noted that your light in master mode you need to change the setting to the slave mode to control the light by dmx or save the last transmission record If light not stab...

Page 7: ...sockets The quantity that can be connected is 33 fixtures maximum After 33 fixtures you will need to use a new power outlet They must be the same fixtures DO NOT mix fixtures Panta V7 Wireless Profile...

Page 8: ...very 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew ng...

Page 9: ...or replacement thereof including parts at the sole discretion of Rasha Professional A S Co All products covered by this warranty were manufactured after January 1 2006 and bear identifying marks to th...