VENTED MODELS IMPORTANT!
CHIMNEY DAMPER MUST BE WIDE OPEN! THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.
DAMPER AND GLASS DOORS MUST BE FULLY OPEN BEFORE LIGHTING OR BURNING FOR PROPER
VENTILATION AND TO PREVENT HEAT DAMAGE TO VALVE.
ALL APPLICATIONS - IMPORTANT INFORMATION
•
This appliance is equipped with a Safety Pilot System designed to shut itself off if enough fresh air is not available.
Additional ventilation may be optained by opening a window or a door to another room.
•
Matches, paper, garbage, or any other foreign material MUST NOT be thrown on top of burner medium or into
the flames.
•
Avoid contact with the burner, burner medium, grate or any other part which may be hot.
•
Always ensure that the fireplace screen is closed when the appliance is operating.
NOTE: Any beeping or unexpected shutdown may be the over-temperature safety feature in the receiver. If tis
happens, move the receiver into a cooler area, and/or use the RH3 remote house.
REMOTE RECEIVER PLACEMENT (“-SE AND “-RE” MODELS)
FIGURE 31
C) Black Volcanic
Ash used as
Floor dressing.
The Remote Receiver (-RE and -SE models) (Figure 31) can be adversely affected by heat and must be placed as far
forward and to the side of your ALTERNA™ as possible (Figure 31A). Our optional Ceramic Remote House
accessory (Figure 31B, Item “RH3”), offers heat protection for the Remote Receiver while being pleasing to the eye
(remove plastic heat shield form receiver before placing inside remote house). When connecting receiver to Motor drive
(“-RE” models) or Solenoid (“SE models) be sure to match red and black connectors, red to red and black to black).
Volcanic Ash Placement: (purchase separately)
Volcanic Ash should only be used on the firebox floor as floor dressing (Figure 31C below).
DO NOT place Volcanic Ash (or any other material) on top of the burner!!!
A) Remote Receiver for
“RE” and “SE”
Models
Black Volcanic Ash
used to help conceal
Flex connector
and wiring
B)