background image

TWO YEAR CONSUMER PRODUCT WARRANTY

The  following warranty has been drafted to comply with the MAGNUSON-MOSS WARRANTY ACT applicable to
products manufactured after July 4, 1975. It replaces and supersedes any warranty in this package or in any printed
literature.

LIMITED WARRANTY:

RASMUSSEN IRON WORKS INC, 12028 E.
Philadelphia Street, Whittier California, U.S.A.., Warrants
this Gas Log Set and accessories against defects in
materials and workmanship, and suitable for a particular
purpose, for a period of:

(1) LOG CASTING - All logs are guaranteed against
burnout in the original installation for two years from date
of initial purchase.

(2) BURNERS - 2 years from date of initial purchase.

(3) SAFETY CONTROLS - 2 years from date of initial
purchase.

THIS WARRANTY IS FOR THE BENEFIT O F
THE ORIGINAL PURCHASER.

WARRANTY ADJUSTMENT:

(1) RASMUSSEN agrees to repair or furnish a
replacement for, but not remove or install any product or
component which proves defective within the above
warranty and appropriate time periods stated.

(2) BUYER shall notify RASMUSSEN of any defect
within this warranty no later than thirty (30) days after a
defect is discovered.

(3) No product will be accepted for return or replacement
without written authorization of RASMUSSEN. Before
returning merchandise, write to RASMUSSEN giving full
details of the complaint and a copy of sales receipt or
other evidence of purchase date. Merchandise returned
without proof of purchase date will be serviced out-of
warranty at our prevailing service and parts rates. If
merchandise was damaged in transit, file claim
immediately with the carrier. Products returned must be
addressed as follows:

RASMUSSEN IRON WORKS INC

1 2 0 2 8   E .   P H I L A D E L P H I A   S T R E E T

WHITTIER CALIFORNIA 90601

Shipping charges must be pre-paid by the buyer.
REPAIR OR REPLACEMENT UNDER THIS
WARRANTY WILL BE SHIPPED FREIGHT
C O L L E C T .

EXCLUSIONS FROM WARRANTY:

(1) The foregoing warranty is limited solely as set forth
herein and applies only for the periods designated
above.

(2) RASMUSSEN shall not be liable for any loss,
damage, incidental or consequential damages of any
kind, whether based upon warranty, contract, or
negligence, arising in connection with the sale, use, or
repair of the product. Some states do not allow the
exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not
apply  to you.

(3) The maximum liability of RASMUSSEN in connection
with this limited warranty shall not in any case exceed the
contract price paid for the product claimed to be
defective or unsuitable.

(4) This warranty does not extend to any product
manufactured by RASMUSSEN which has been
subjected to misuse, neglect, accident, improper
installation, or use in violation of instructions furnished
by RASMUSSEN. Do not remove Rating Plate/Warning
Tags. These tags serve you and any future user as an
integral safety and identification component of the
CHILLBUSTER gas log heater.  Removing these tags
voids the warranty.

(5) This warranty does not extend to or apply to any unit
which has been repaired or altered at any place other
than RASMUSSEN IRON WORKS INC factory, or by
persons not expressly approved by RASMUSSEN.

(6) Components manufactured by any supplier other
than RASMUSSEN shall bear only that warranty made by
the manufacturer of that product.

(7) Freight damage, cracking from thermal shock, and
color changes occur from causes beyond
manufacturer's control and are not covered by any
warranty.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.

RASMUSSEN IRON WORKS, INC. shall be held
harmless from any and all claims by the buyer as a result
of injury or damage to an ultimate user or other person
caused by the product sold herein by the seller to the
buyer, whether the injury or damage results from the
assembly, installation, operation, shipment, storage or
manufacture of this product. RASMUSSEN IRON
WORKS, INC. makes no warranties, expressed or
implied, other than those expressly stated herein.

CB WARRRANTY 2-03

12

Summary of Contents for AGA Chillbuster IR

Page 1: ...enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters bathrooms or recreational vehicles WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage p...

Page 2: ...es instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet...

Page 3: ... proper operation 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Pressure Testing VENTED and VENT FREE 1 Use Pr...

Page 4: ...e Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr then space is CONFINED If the Actual Btu Hr Used is less than Maximum Supportable Btu Hr then space is UNCONFINED In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr th...

Page 5: ... floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are m...

Page 6: ...0 plus 10 FIREBOX Standard Fireplace Hood with a minimum 4 inch horizontal projection such as those offered by most major fireplace manufacturers Figure 2 IF YOU CANNOT MEET THESE MINIMUM CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page 3 ALL APPLICATIONS VENTED and VENT FREE OPERATION ASSEMBLY AND INSTALLATION Installing Chillbuster Burner Unit ...

Page 7: ...LOGs across the FRONT and REAR logs with the LOCATOR PINS inserted into the drilled holes located on the bottom of both LARGE TOP LOGs Figures 7 and 8 3 Place R and L SMALL TOP LOGs across the FRONT LOG and LARGE TOP LOGs with the LOCATOR PINS inserted into the drilled holes Figures 7 and 8 To ensure optimum performance logs must be placed on burner as depicted Do not Allow Top Logs to Cross Flame...

Page 8: ...s the Gas Control Valve Figure 9 knob is turned to ON 8 To turn the Infra Red Heater off turn the Infra Red front Burner Valve clockwise to OFF NOTE turning the Gas Control Valve to OFF simultaneously stops gas flow to both the Rear Gas Burner and the Infra Red burner Shutting Down 9 Turning the Gas Control Valve to OFF will allow the pilot to remain lit while shutting down both the Rear Burner an...

Page 9: ... Valve clockwise to OFF NOTE Turning KNOB A Main Gas Control to OFF stops gas flow to both the Rear Gas Burner and the Front Infra Red burner simultaneously Shutting Down 11 Turning KNOB A Main Gas Control to OFF allows the pilot to remain lit while shutting down both the Rear Gas Burner and the Front Infra Red Heater See Figure 11 12 For complete shutdown including pilot slightly push control KNO...

Page 10: ...rt for optimum performance Air shutters which have been closed or are obstructed with debris will not allow sufficient combustion air into burner Air shutters should be periodically cleaned of debris Use compressed air or a soft bristle brush to clear pilot and burner s air intakes Air shutters should not be altered from factory settings WARNING Failure to keep the primary air opening s of the bur...

Page 11: ...Burner Orifice 38 Front Burner Gas Valve 2 Top Log Large Left 11a Carryover Tube Orifice Holder 39 Front Burner Valve Knob 3 Rear Log Holder P 21 S25 Infrared Burner 40 Regulator Outlet Brass 4 Front Log 12 Lighter Tube CRA B M Manual 41 3 8 x 3 8 Street EL 5 Grate 13 Cylindrical Spacer 30 Regulator Input Brass tapped 6 Top Log Small Right 14 Burner back 31 Gas Pressure Reg N CRA B T Thermostat 7 ...

Page 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Page 13: ... Knob B Pilot Set Screw under plate here OFF ON KNOB A Main Gas Control KNOB B Rear Gas Burner Thermostat KNOB C Infra red Front Burner Valve 13 ...

Reviews: