Instructions for Rasmussen Chillbuster 

"Evening Embers" 

(C-5)

Manual, Switch or Remote Control

Natural and Propane Gas Log Room Heater Models:

18", 24" or 30" THREE BURNER Manual Control

(HF)(18, 24,30)-C5A-M-(N,P)

18", 24" or 30" THREE BURNER Switch Control

(HF)(18, 24,30)-C5A-S-(N,P)

18", 24" or 30" THREE BURNER Remote Control

(HF)(18, 24,30)-C5A-R-(N,P)

18", 24" or 30" THREE BURNER Manual Control

(HF)(18, 24,30)-C5B-M-(N,P)

18", 24" or 30" THREE BURNER Switch Control

(HF)(18, 24,30)-C5B-S-(N,P)

18", 24" or 30" THREE BURNER Remote Control

(HF)(18, 24,30)-C5B-R-(N,P)

THESE GAS LOG HEATERS ARE CERTIFIED TO THE FOLLOWING STANDARDS:

UNVENTED ROOM HEATER ANSI Z21.11.2a 2001

VENTED DECORATIVE APPLIANCE ANSI Z21.60b 2001 * CGA 2.26b-2001

Read these Instructions carefully and retain them for future use.

WARNING:   Improper installation, adjustment, alteration, service or maintenance can

cause property damage, personal injury or loss of life. Read these instructions thoroughly

before installation.  For assistance or additional information, consult your gas log dealer,

qualified installer, service agency or gas supplier.

Design certified for installation only in a  solid-fuel burning masonry or UL 127 factory-built  fireplace or
in a listed ventless firebox enclosure.  DO NOT install this appliance in a factory-built fireplace that
includes instructions stating it has not been tested or should not be used with unvented gas logs.

Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters, bathrooms or

recreational vehicles.

WARNING: If the information in this manual is not followed exactly, a fire or explosion

may result causing property damage, personal injury or loss of life

   .

This appliance may be installed in an after
market, permanently located,
manufactured (mobile) home, where not
prohibited by local codes.

This appliance is for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do
not use any phone in your building.

Immediately call your gas supplier from
a neighbors phone. Follow the gas
supplier's instructions.

If you cannot reach your gas supplier,
call the fire department.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance.

   .

 Installation and service must be performed by a qualified installer, service

agency or the gas supplier.

   .

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Section "PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION
AIR" (pages 4 and 5.)

   .

1

Summary of Contents for CHILLBUSTER 5

Page 1: ...in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs...

Page 2: ...s instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by...

Page 3: ...peration 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not a...

Page 4: ...Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr the...

Page 5: ...floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may...

Page 6: ...CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page 3 ALL APPLICATIONS VENTED and VENT FREE OPERATION Installing Chillbuster 5 Burner Unit Into Firepl...

Page 7: ...oser the pieces the better the glowing ember effect WARNING Excessive amounts of Ember Material or Ember Material which is too tightly packed or exposed ports on Front or Middle burner can result in d...

Page 8: ...ers Rear Burner All positions are controlled through the Valve Knob CAUTION Cycling rapidly between burner settings can result in VENTURI LIGHT OFF This is characterized by a loud air flow noise resul...

Page 9: ...From THERMOPILE Valve Terminals 3 Way Control Selector Switch To ACCESSORY CONTROL Outside Terminal Piggy Back Outside Terminal instructions for individual Remote Accessory Options are included with t...

Page 10: ...resistant log in which the CRACKLER Sound Generator option for both the F10 AB and IRRC wireless remotes may be located NORMAL OPERATING CHARACTERISTICS Each and every CHILLBUSTER that leaves the fact...

Page 11: ...our log set When ordering parts always specify From information available on name plate attached to grate the following 1 Model number of the log set 2 Serial number of the log set 3 Type of gas natur...

Page 12: ...as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty c...

Page 13: ...CHANGES 2 03 page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 13...

Reviews: