background image

Do not operate in a dirty firebox or in a previously used firebox which has not had all soot completely removed or it's
chimney flue cleaned. Previously used fireboxes must have flue and stack professionally cleaned by a chimney 
sweep.  Additionally, firebox walls and damper must also be thoroughly cleaned of all burn residue and soot using 
a damp cloth, sponge or brush.

Do not operate this set with any logs other than the RASMUSSEN CHILLBUSTER Refractory Logs specifically

designed and approved for use with this Burner System.

Do not use with blower inserts or heat exchangers.

If used, glass doors must be wide open when burner is on.

Do not remove Rating Plate/Warning Tags. These tags serve you and any future user as an integral safety and 
identification component of the CHILLBUSTER gas log heater.  Removing these tags voids the warranty.

WARNING:  Do not allow fans to blow directly into fireplace.  Avoid any drafts that alter burner
flame patterns.
 Do not place blower inside area of firebox. Ceiling fans may create drafts that alter burner flame 
patterns. Sooting and improper burning may occur. Sooting can settle on surfaces outside the fireplace.

During periods of heavy use, inspect frequently for evidence of sooting. If sooting is present, discontinue
use until source of sooting is determined and corrected.

Maintain log positioning (Page 7) at all times.

HOW TO ORDER PARTS

Parts can be ordered through the supplier from whom
you purchased your log set.
When ordering parts, always specify (From information
available on name plate attached to grate) the following:

1. Model number of the log set.
2. Serial number of the log set.
3. Type of gas (natural or propane Gas).
4. The name of the part and part number from parts list.

Save these instructions

Manufactured By:  RASMUSSEN IRON WORKS,  INC. 

12028 E. Philadelphia Street
Whittier, California  90601

CONSUMER RECORD CARD

Fill in blanks below for your permanent record.

DATE PURCHASED                

              

              

              

MODEL NO.

              

              

              

            

DATE INSTALLED

              

              

              

              

S E R I A L   N O .

              

              

              

              

INSTALLED BY:

              

              

              

              

G A S   T Y P E :

              

              

              

              

DEALER:

              

              

              

            

3

2

1

4

5

6

7

1 0

4a

8

9

1 1

1 2

1 3

1 4

1 5

1 6

1 7

1 8

1 9

2 0

2 1

2 2

2 3

2 4

2 5

2 6

3 0

3 1

3 2

3 3

3 4

4 0

4 1

4 2

2 7

5 0

5 1

1.

Center Log H-13 (small)

10.

Rear Log

20.

3/8" Valve/Reg output gas

31.

1/4" Middle Burner Supply

2.

Center Log S-25 (Large)

11.

Rear Burner

Tubing

32.

1/4" Front Burner Supply

3.

Left Top Log H-14 (18" & 24")

12.

Rear Burn. Orifice (N or LP)

21.

1/4" Pilot Supply Tubing

33.

Manual  Gas Valve

4.

Left Top Log Rear H-10 (30"

13.

Rear Burner Orifice

22.

ODS Pilot (N or LP

34.

Regulator (N) or (P)

Model)

Holder

MV or Standard/)

4a.  Left Top Front  D7 (30" Model)

14.

Middle Burner

23.

Grate

C5-A/B-S (Accessory Switch)

5.

Right Top Log D-7 (18" and 24"

15.

Mid Burn. Orifice (N or LP)

24.

Valve Knob

40.

MV Valve (3.5; 5.0 or 10.0)

Models)

16.

Mid Burner Orifice

25.

Push Button Piezo Ignitor

41.

3 Way Switch (S Model)

6.

Right Top Log H-15 (30"

Holder

26.

Ember Material

42.

Rear Burner  Control Valve

Model)

17.

Front Burner

27.

3/8" Gas Supply Connector

7.

Left Middle Log

18.

Front Burn. Orifice (N or LP)

C5-A/B-R (Remote)

8.

Right Middle Log

19.

Front Burner Orifice

C5-A/B-M (Manual)

50. Remote Valve and  Receiver

9.

Front Log

Holder

30

1/4" Rear Burner Supply

51. Transmitter

11

Summary of Contents for CHILLBUSTER 5

Page 1: ...in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs...

Page 2: ...s instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by...

Page 3: ...peration 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not a...

Page 4: ...Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr the...

Page 5: ...floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may...

Page 6: ...CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page 3 ALL APPLICATIONS VENTED and VENT FREE OPERATION Installing Chillbuster 5 Burner Unit Into Firepl...

Page 7: ...oser the pieces the better the glowing ember effect WARNING Excessive amounts of Ember Material or Ember Material which is too tightly packed or exposed ports on Front or Middle burner can result in d...

Page 8: ...ers Rear Burner All positions are controlled through the Valve Knob CAUTION Cycling rapidly between burner settings can result in VENTURI LIGHT OFF This is characterized by a loud air flow noise resul...

Page 9: ...From THERMOPILE Valve Terminals 3 Way Control Selector Switch To ACCESSORY CONTROL Outside Terminal Piggy Back Outside Terminal instructions for individual Remote Accessory Options are included with t...

Page 10: ...resistant log in which the CRACKLER Sound Generator option for both the F10 AB and IRRC wireless remotes may be located NORMAL OPERATING CHARACTERISTICS Each and every CHILLBUSTER that leaves the fact...

Page 11: ...our log set When ordering parts always specify From information available on name plate attached to grate the following 1 Model number of the log set 2 Serial number of the log set 3 Type of gas natur...

Page 12: ...as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty c...

Page 13: ...CHANGES 2 03 page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 13...

Reviews: