AGA "CHILLBUSTER I" 

12028 E. Philadelphia St. Whittier , CA 90601  U.S.A.

(562) 696-8718        FAX (562) 698-3510

E-Mail: gaslogs@riwinc.com  Web http://www.riwinc.com

CB-1 2-03

A s s e m b l y ,   I n s t a l l a t i o n ,   a n d   O p e r a t i o n

Instructions for Rasmussen "Single Burner"

Manual, Switch, or Remote

Natural and Propane Gas Log Room Heater Models:

18" or 24" SINGLE BURNER Manual Control (K,W,KW)(18, 24)-C1A,C-M-(N,P)

30" SINGLE BURNER Manual Control (K,W,KW)(30)-C1B,D-M-(N,P)

18", 24" or 30" DOUBLE FACE Manual Control DF(K,W,C)(18,24,30)-DFC1,C1C-M-(N,P)

18" or 24" SINGLE BURNER Switch Control (K,W,KW)(18, 24)-C1A,C-S-(N,P)

30" SINGLE BURNER Switch Control (K,W,KW)(30)-C1B,D-S-(N,P)

18", 24" or 30" DOUBLE FACE Switch Control DF(K,W,C)(18, 24, 30)-DFC1,C1C-S-(N,P)

30" SINGLE BURNER Remote Control (K,W,KW)(30)-C1B,D-R-(N,P)

18" or 24" SINGLE BURNER Remote Control (K,W,KW)(18, 24)-C1A,C-R-(N,P)

18", 24" or 30" DOUBLE FACE Remote Control DF(K,W,C)(18, 24, 30)-DFC1,C1C-R-(N,P)

Read these Instructions carefully and retain them for future use.

THESE GAS LOG HEATERS ARE CERTIFIED TO THE FOLLOWING STANDARDS:

UNVENTED ROOM HEATER ANSI Z21.11.2a 2001

VENTED DECORATIVE APPLIANCE ANSI Z21.60b 2001 * CGA 2.26b-2001

Design certified for installation only in a  solid-fuel burning masonry or UL 127 factory-built  fireplace or

in a listed ventless firebox enclosure.

DO NOT install this appliance in a factory-built fireplace that includes instructions stating it has not been

tested or should not be used with unvented gas logs.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

causing property damage, personal injury or loss of life

   .

WARNING:

Improper installation,    adjustment,

alteration, service or maintenance can cause
property damage, personal injury or loss of life. Read
these instructions thoroughly before installation.
For assistance or additional information, consult
your gas log dealer, qualified installer, service
agency or gas supplier.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use
any phone in your building.

Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier's
instructions.

If you cannot reach your gas supplier,
call the fire department.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

.

INSTALLATION AND SERVICE: Installation and service must be performed by a

qualified installer, service agency or the gas supplier.

.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Section "PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION
AIR" (pages 4 and 5.)

   .

1

Summary of Contents for DFC18-DFC1-R-N

Page 1: ...isted ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration ...

Page 2: ...e a CHILLBUSTER is installed 3 The minimum size in inches of the fireplace in which this CHILLBUSTER is to be installed must be as follows SET SIZE MODEL NUMBER FRONT WIDTH HEIGHT DEPTH 18 24 30 18 24 30 18 24 30 18 24 30 K W KW 18 C1C M S R N P 23 000 BTU HR K W KW 24 C1C M S R N P 23 000 BTU HR K W KW 30 C1D M S R N P 23 000 BTU HR K W KW 18 C1A M S R N P 40 000 BTU HR K W KW 24 C1A M S R N P 40...

Page 3: ...BUSTER is very realistic in appearance it is not a real wood burning fireplace Matches paper garbage or any other material must not be thrown on top of the logs or into the flames Avoid contact with the logs grate or any other part which may be hot Always ensure that the fireplace screen is closed when the appliance is operating State or local codes may only allow operation of this appliance in a ...

Page 4: ...rtable Btu Hr 72 000 Btu Hr Actual Btu Hr Used 11 840 Btu Hr Excess Non Supportable Btu Hr In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr the space would be considered a Confined Space requiring you to either increase the Maximum Supportable Btu Hr decrease the Actual Btu Hr Used or operate as a Vented Appliance see page 3 Adequate Combustion And Ventilation A...

Page 5: ...mbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are more affected by carbon monoxide than others Early s...

Page 6: ...BOX Figure 3 4 Standard Fireplace Hood with a minimum 4 inch horizontal projection beyond vertical surface ABOVE hood as provided by most major fireplace manufacturers IF YOU CANNOT MEET THESE MINIMUM CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page Three ALL APPLICATIONS VENTED and VENT FREE OPERATION ASSEMBLY AND INSTALLATION INSTALLING CHILLBU...

Page 7: ...P VIEW FRONT VIEW Front Log Rear Log Top Log Large R Top Log Large L Top Log Small L Top Log Small R Front Log Rear Log Top Log Large R Top Log Small R Top Log Large L Top Log Small L Main burner 24 30 sets 24 30 sets Figure 5 Figure 6 WARNING Failure to position parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damag...

Page 8: ... Valve Knob until air is bled and gas flows to pilot Press PIEZO IGNITOR Button Figure 9 to light pilot Continue to hold valve knob in until Pilot remains lit when knob is released 5 Slowly turn knob to ON The rear burner will light from the pilot The front burner will light from the carry over tube 6 If appliance fails to light or if pilot goes out repeat steps 1 through 5 7 For complete shutdown...

Page 9: ...rared and operate instantly and requires you to aim and hold the transmitter for 1 to 3 seconds to operate Manual Operation Receiver switch position ON or OFF does not require batteries Remote Operation Requires good batteries If you turn the gas log on using the remote control and then turn the set off by sliding the receiver switch from REMOTE to OFF when you replace the switch to REMOTE it will...

Page 10: ... the area around the CHILLBUSTER free and clear from debris From time to time visually check pilot and burner flames for proper appearance Figures 15 and 16 Normal flame color should be yellow body surrounded by a hard blue haze The pilot air shutters and burners must be free of lint and dirt for optimum performance Air shutters which have been closed or are obstructed with debris will not allow s...

Page 11: ... 20 21 22 24 26 31 30 23 25 2 8 32 33 40 41 42 43 50 51 60 61 62 1 O22 Burner 40 000 BTU or 9 Push Button Ignitor DFC1 C1C Double Face 43 Valve Knob O38 Burner 23 000 BTU 10 Inlet Aluminum Connector 30 Grate 2 Pilot Manifold Tubing C1A C and C1B D 31 Front Logs 2 MILLIVOLT SWITCH SETS 3 O D S Assembly Natural or 20 Grate 32 Top Logs 2 Large 50 Manual 3 Way Switch and O D S Assembly Propane 21 Fron...

Page 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Page 13: ...CPW CB 2 96 CHANGES next page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 13 ...