R

T r i p l e   B u r n e r   D e c o r a t i v e   G a s   L o g   A p p l i a n c e 

A s s e m b l y ,   I n s t a l l a t i o n ,   a n d   O p e r a t i o n   I n s t r u c t i o n s   f o r 

R a s m u s s e n   T r i p l e   B u r n e r   D e c o r a t i v e   G a s   A p p l i a n c e   M o d e l s : 

18"  Match Lighted

(PA, PR, MA, NA, XF, WSA, LS,UA)(18)/(XF, LS)(21)/(PA, MA, NA, WSA,UA)(24Z)-TR18-J-(N)

18"  Manual Pilot Control (PA, PR, MA, NA, XF, WSA, LS,UA)(18)/(XF, LS)(21)/(PA, MA, NA, WSA,UA)(24Z)-TR18-M-(N,P)

18"  Switch Pilot Control

(PA, PR, MA, NA, XF, WSA, LS,UA)(18)/(XF, LS)(21)/(PA, MA, NA, WSA,UA)(24Z)-TR18-S-(N,P)

24"  Match Lighted

(PA, PR, MA, NA, XF, WSA, LS,UA)(24)-TR24-J-(N)

24"  Manual Pilot Control (PA, PR, MA, NA, XF, WSA, LS,UA)(24)-TR24-M-(N,P)

24"  Switch Pilot Control

(PA, PR, MA, NA, XF, WSA, LS,UA)(24)-TR24-S-(N,P)

30"  Match Lighted

(PA, PR, MA, NA, XF, WSA, LS,UA)-(36)-TR30-J-(N)

30  Manual Pilot Control (PA, PR, MA, NA, XF, WSA, LS,UA)-(36)-TR30-M(N,P)

30"  Switch Pilot Control

(PA, PR, MA, NA, XF, WSA, LS,UA)-(36)-TR30-S-(N,P)

WARNING: If you do not follow these instructions exactly, a fire or

explosion may result causing property damage, personal injury or loss of

life.

Read these Instructions carefully and retain them for future use.

THESE APPLIANCES ARE CERTIFIED TO THE FOLLOWING STANDARDS:

• TR-18; TR-24; TR-30-(M) Manual or (S) Switch: Vented Decorative Appliance ANSI Z21.60/CGA 2.26-M96

• TR-18; TR-24; TR-30-(J) Match Lit: AGA 7-94 (Natural Gas Only)

WARNING: 

Improper 

installation,

alteration,  service  or  maintenance  can
cause  injury  or  property  damage.    Read
these 

instructions 

thoroughly 

before

installation.      For  assistance  or  additional
information,  consult  your  gas  log  dealer,
qualified  installer,  service  agency  or  gas
supplier.  

FOR YOUR SAFETY

Do  not  store  or  use  gasoline  or  other
flammable vapors and liquids in the vicinity
of this or any other appliance.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do
not use any phone in your building.

Immediately call your gas supplier from
a  neighbors  phone.    Follow  the  gas
suppliers instructions.

If you cannot reach your  gas  supplier,
call the fire department.

Summary of Contents for TR 3000 SERIES

Page 1: ...M N P 30 SwitchPilotControl PA PR MA NA XF WSA LS UA 36 TR30 S N P WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Read these Instructions carefully and retain them for future use THESE APPLIANCES ARE CERTIFIED TO THE FOLLOWING STANDARDS TR 18 TR 24 TR 30 M Manual or S Switch Vented Decorative Appliance ...

Page 2: ... column on LP gases 8 The maximum inlet gas supply pressure shall be 7 inches of water column on natural gas and 14 inches of water column on LP gases 9 The installation and the provision for combustion and ventilation air must conform with the National Fuel Gas Code ANSI Z223 1 Latest Edition 10 The gas log set and its individual shutoff valve must be disconnected from the gas supply piping syste...

Page 3: ...lue MUST BE FREE OF ANY OBSTRUCTIONS 2 Turn off gas supply to fireplace 3 Clean fireplace floor of any ashes 4 Attach damper clamp over edge of fireplace damper blade as shown When installed properly damper clamp prevents accidental full closure of damper See FIGURE 1 If unable to install provided damper clamp consult IMPORTANT INFORMATION on front page of these directions Damper Stop Clamp Damper...

Page 4: ...ion 1 Place lighted match on right side of FRONT BURNER TRAY near inlet end of burner FIGURE 3 DO NOT HOLD MATCH IN HAND 2 Slowly open PRIMARY GAS SUPPLY VALVE and wait for burner to light FIGURE 3 3 Adjust PRIMARY GAS SUPPLY VALVE to obtain desired flame height Ensure adequate gas supply is available to operate FRONT BURNER TRAY and MIDDLE BURNER TRAY TR 18 24 30 M MANUAL PILOT CONTROL PILOT LIGH...

Page 5: ...knob until air is bled and gas flows to pilot Press PIEZZO IGNITOR BUTTON FIGURE 8 to light pilot Continue to depress MILLIVOLT GAS VALVE Knob until pilot remains lit when knob is released approximately 60 to 90 seconds 6 If Pilot does not remain lit repeat steps 1 through 5 and allow more time after Pilot Lighting before releasing knob PILOT FLAME ADJUSTMENT TR 18 24 30 S SWITCH PILOT CONTROL PIL...

Page 6: ...RC wireless remotes may be located REAR BURNER ADJUSTMENT TOP BURNER CONTROL VALVE OFF ON FIGURE 11 REAR BURNER CONTROL VALVE REAR BURNER CONTROL VALVE Once the burners have been lit the REAR BURNER can be adjusted independently of the MIDDLE and BOTTOM BURNERS by adjusting the REAR BURNER CONTROL VALVE FIGURES 3 11 To achieve the desired flame effect turn the REAR BURNER CONTROL VALVE countercloc...

Page 7: ...LER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 PARTS LIST 1 Pine Cone 10 Gas Distribution Assembly 17 Grate 23 Primary Connector Tubing 2 Top Log Small Left 11 Rear Cover Plate 18 Middle Burner Manifold 24 Control Mounting Plate 3 Top Log Large left 12 Top Burner Control Valve Tubing 25 Gas Regulator Assembly 4 Top Log Small Right Manifold Tubing 19 Middle ...

Page 8: ... RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSE...