15
Cleaning and Maintenance
1. Always unplug the unit before cleaning, maintenance or moving. To avoid danger,
unplug the unit and wait until the fan stop running before cleaning.
2. Ensure that the fan is switched off from the supply mains and unplug before removing
the guard.
3. Clean the surface of fan with a soft damp cloth.
4. After cleaning, please dried up the fan before use.
How To Disassemble
1. Remove the screw under the front guard by screwdriver.
2. Pull the net buckle, and then remove the front guard.
Installation
1. Joint the tube to the base
①
Remove the screw from the base of tube by screw driver. (Figure 1)
②
Align the hole of column with column of the tube, then install the tube to the base.
(Figure 2)
③
To lock the screw by screwdriver. (Figure 3)