background image

Raspberry PI

vending solution

(RASPIVEND)

v.28.11.2016

Quick Reference

© 2016 – AUTOMATROM SRL – www.vendingtools.ro

Summary of Contents for RASPIVEND

Page 1: ...Raspberry PI vending solution RASPIVEND v 28 11 2016 Quick Reference 2016 AUTOMATROM SRL www vendingtools ro...

Page 2: ...12 10 Set maximum credit 12 11 Reset the current credit 13 12 Return change 13 13 Set current cash credit 13 14 Poll credit and devices status 14 15 Reset all devices status 17 16 Cashless INIT 17 17...

Page 3: ...6 31 RTCGet 36 V High level mode with Python 3 service daemon 37 1 Configuring Python 3 37 2 MDBBillInit 37 3 MDBBillEnable 37 4 MDBBillDisable 38 5 MDBCoinInit 38 6 MDBCoinEnable 38 7 MDBCoinDisable...

Page 4: ...shlessRevalue 48 28 MDBCashlessEndSession 48 29 SetMUXChannel 48 30 CCTHopperInit 49 31 CCTHopperDispense 49 32 CCTHopperCheckDispense 50 33 CCTHopperDispenseCipher 50 2016 AUTOMATROM SRL www vendingt...

Page 5: ...lexers to select the proper communication channel b A high level communication method that simplifies the user interface development offering a language independent support A Low level mode In low lev...

Page 6: ...e Low level High level MDB coin acceptor changer yes yes MDB bill validator yes yes MDB cashless 1 yes yes MDB cashless 2 yes yes ccTalk yes Only with Python 3 RS232 1 yes yes RS232 2 yes yes GPRS com...

Page 7: ...Also the variable length depends on subcommand CRC Defines the message checksum The CRC is calculated as an XOR of all message bytes including the HEADER For example the command to enabled the bill va...

Page 8: ...tible The system eliminates the separate 5V microUSB power supply for Raspberry PI You will only need one power supply for the entire system 2 Connector description J17 POWER connector for the RASPIVE...

Page 9: ...nd alos the power and GND pins Pins marked with red background are reserved for RASPIVEND Pin No Rpi function RASPIVEND Pin No Rpi function RASPIVEND 1 3 3V 3 3V 2 5V 5V 3 GPIO2 SDA1 I2C MODEM DCD 4 5...

Page 10: ...e GPIO22 GPIO27 GPIO17 Selected peripheral the peripheral currently connected to RasPI 0 0 0 MDB 0 0 1 RS232 1 J10 0 1 0 RS232 2 J11 0 1 1 VTLCOMBUS 1 0 0 ccTalk 1 0 1 Modem 2 MDB bill validator initi...

Page 11: ...a are detailed in the MDB documentation This command is optional and is used only if you need to handle some lower informations bill validator MDB level software version ISO country code etc 6 Coin ac...

Page 12: ...the contained data are detailed in the MDB documentation This command is optional and is used only if you need to handle some lower informations coin acceptor changer MDB level software version ISO c...

Page 13: ...350cents or 3 50EUR 3 50USD CRC RASPIVEND answer 0xFE 0x52 0x03 0xFB command execution failed 0xFC command successfully executed 0xFD command CRC error CRC This command will start returning change if...

Page 14: ...ns last 4 bill validator status If the register has the value 0xFFFFFFFF then the bill validator is not initialized The rightmost byte of this register is the last status COIN acceptor changer status...

Page 15: ...Bill Removed A bill in the escrow position has been removed by an unknown means A BILL RETURNED message should also be sent 0x08 Cash Box out of position The validator has detected the cash box to be...

Page 16: ...ed 0x07 Tube Jam A tube payout attempt has resulted in jammed condition 0x08 ROM checksum error The changers internal checksum does not match the calculated checksum 0x09 Coin Routing Error A coin has...

Page 17: ...ess status codes 15 Reset all devices status HEADER CMD SUBCMD PARAMETERS CRC 0xFE 0x50 0x02 none 0xAC RASPIVEND answer 0xFE 0x50 0x02 0xFB command execution failed 0xFC command successfully executed...

Page 18: ...S CRC 0xFE 0x53 0x03 CASHLESS NUMBER 0x01 cashless 1 0x02 cashless 2 CRC RASPIVEND answer 0xFE 0x53 0x03 0xFB command execution failed 0xFC command successfully executed 0xFD command CRC error CRC Thi...

Page 19: ...BER 0x01 cashless 1 0x02 cashless 2 CRC RASPIVEND answer 0xFE 0x53 0x06 0xFB command execution failed 0xFC command successfully executed 0xFD command CRC error CRC This command must be sent after a su...

Page 20: ...CASHLESS NUMBER 0x01 cashless 1 0x02 cashless 2 CRC RASPIVEND answer 0xFE 0x53 0x09 CASHLESS SETUP 8 bytes CASHLES EXPANSION INFORMATION 30 bytes CRC This command will return the low level settings o...

Page 21: ...0xFC command successfully executed 0xFD command CRC error CRC This command will set the date and hour into the RTC 27 RTC get HEADER CMD SUBCMD PARAMETERS CRC 0xFE 0x50 0x04 none CRC RASPIVEND answer...

Page 22: ...2016 AUTOMATROM SRL www vendingtools ro...

Page 23: ...etd Proceed to xinetd installation according to your distribution specifications 2 MDBBillInit GUI command Command Parameters Comments MDBBillInit none RASPIVEND daemon answer Answer Parameters Commen...

Page 24: ...Parameters Comments MDBCoinInit success or MDBCoinInit failed This command will initialize the attached MDB coin acceptor changer 6 MDBCoinEnable GUI command Command Parameters Comments MDBCoinEnable...

Page 25: ...e 5 BillValue 10 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 Manufacturer ITL SerialNumb...

Page 26: ...true ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false Manufacturer NRI SerialNumber NRI00136295 Model 046G 46 F40...

Page 27: ...you have to set this value to 100 RASPIVEND daemon answer Answer Parameters Comments MDBSetMaxCredit NNNN This command will return the value you have sent For safety reasons eliminate the communicatio...

Page 28: ...read this variable by issuing the MDBPoll command RASPIVEND daemon answer Answer Parameters Comments MDBSetCurrentCredit NNNN This command will return the value you have sent For safety reasons elimi...

Page 29: ...sent value 15 MDBSetChangeOK GUI command Command Parameters Comments MDBSetChangeOK none RASPIVEND daemon answer Answer Parameters Comments MDBSetChangeOK success or MDBSetChangeOK failed This comman...

Page 30: ...ins the last 4 hexadecimal coin acceptor status codes according with the Table 3 on page 15 The leftmost value is the older one CaslessStat contains the last 4 hexadecimal cashless devices status code...

Page 31: ...of the cashless to be enabled 1 for the first cashless device and 2 for the second cashless device RASPIVEND daemon answer Answer Parameters Comments MDBCashlessEnable success or MDBCashlessEnable fa...

Page 32: ...ms for service maintenance reasons 23 MDBCashlessVendRequest GUI command Command Parameters Comments MDBCashlessVendRequest NNNN Set the value of the requested credit will be withdrawn from the custom...

Page 33: ...VendSuccess N N is the address of the cashless to withdraw 1 for the first cashless device and 2 for the second cashless device RASPIVEND daemon answer Answer Parameters Comments MDBCashlessVendSucces...

Page 34: ...ximum revalue settings for the cashless system You have to set the cashless revalue only in it s aloud range If you will not manage this then the cashless can randomly goes to overflow 28 MDBCashlessE...

Page 35: ...the product When you receive the correct combination as a response then you have to commit the command with the command KBSetOK RASPIVEND daemon answer Answer Parameters Comments KeyboardSet ABCD or K...

Page 36: ...ed 31 RTCGet GUI command Command Parameters Comments RTCGet This command will read the date and time informations from the non volatile RTC on the RASPIVEND board This command is useful to help you se...

Page 37: ...3 The only dependency for this application is pyserial library version 3 0 1 or higher 2 MDBBillInit GUI command Command Parameters Comments MDBBillInit none RASPIVEND daemon answer Answer Parameters...

Page 38: ...Parameters Comments MDBCoinInit success or MDBCoinInit failed This command will initialize the attached MDB coin acceptor changer 6 MDBCoinEnable GUI command Command Parameters Comments MDBCoinEnable...

Page 39: ...e 5 BillValue 10 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 BillValue 0 Manufacturer ITL SerialNumb...

Page 40: ...true ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false ChangeCoin false Manufacturer NRI SerialNumber NRI00136295 Model 046G 46 F40...

Page 41: ...you have to set this value to 100 RASPIVEND daemon answer Answer Parameters Comments MDBSetMaxCredit NNNN This command will return the value you have sent For safety reasons eliminate the communicatio...

Page 42: ...read this variable by issuing the MDBPoll command RASPIVEND daemon answer Answer Parameters Comments MDBSetCurrentCredit NNNN This command will return the value you have sent For safety reasons elimi...

Page 43: ...sent value 15 MDBSetChangeOK GUI command Command Parameters Comments MDBSetChangeOK none RASPIVEND daemon answer Answer Parameters Comments MDBSetChangeOK success or MDBSetChangeOK failed This comman...

Page 44: ...ins the last 4 hexadecimal coin acceptor status codes according with the Table 3 on page 15 The leftmost value is the older one CaslessStat contains the last 4 hexadecimal cashless devices status code...

Page 45: ...of the cashless to be enabled 1 for the first cashless device and 2 for the second cashless device RASPIVEND daemon answer Answer Parameters Comments MDBCashlessEnable success or MDBCashlessEnable fa...

Page 46: ...ms for service maintenance reasons 23 MDBCashlessVendRequest GUI command Command Parameters Comments MDBCashlessVendRequest NNNN Set the value of the requested credit will be withdrawn from the custom...

Page 47: ...VendSuccess N N is the address of the cashless to withdraw 1 for the first cashless device and 2 for the second cashless device RASPIVEND daemon answer Answer Parameters Comments MDBCashlessVendSucces...

Page 48: ...sion GUI command Command Parameters Comments MDBCashlessEndSession N N is the address of the cashless to close the session 1 for the first cashless device and 2 for the second cashless device RASPIVEN...

Page 49: ...based on those statuses if the init procedure is a success or not In our example the procedure is a success since the test hopper does not support ClearComms command but successfully answered on the...

Page 50: ...ituation the dispense failed and there a remaining NotDispensed coins that could not be supplied It is up to the customer s application to decide if it will try another dispense command or return to t...

Page 51: ...NOTES 2016 AUTOMATROM SRL www vendingtools ro...