POE LAN
INPUT
100-240Vac
SELECTOR
15V 24V
12V SOLAR
INPUT
SELECTOR OUTPUT
12V OUTPUT
9V
12V
{
}
1
2
Phone
WIFI
IPAD
PSP
Thank you for choosing the OMNIPOWER RATEL MICRO UPS.
Before operating this unit, please read the USER MANUAL
carefully to ensure the best possible performance is obtained.
1) OmniPower Ratel 860P
2) AC power cable
3) DC output cables (2 ends)
4) User's manual
5) Warranty card
1 . OMNIPOWER RATEL MICRO UPS package
1) ON/OFF Switch
2) Work status indicator
3) 12Vdc LED Indicator
4) 9Vdc LED Indicator
5) 25
%
BAT
capacity
LED
Indicator
6) 50
%
BAT
capacity
LED
Indicator
7) 75
%
BAT
capacity
LED
Indicator
8) 100
%
BAT
capacity
LED
Indicator
9) Ethernet output interface
(POE output: 15V/24V)
10) LAN Ethernet interface LAN
11) Output Voltage Selector(15V/24V)
12) 12Vdc solar input
13) Output Voltage Selector(9V/12V)
14) Output socket(9V/12V) 5mm
15) Output socket
16) AC input socket
17) Output socket 5V
18) USB (5Vdc) output
2 . Instructions of the components
3 . Features
4 . High compatibilities
2
3
4
5
7
8
6
1
9
10
11
12
13
14
15
16
Ratel 860P
5Vdc OUTPUT
USB
USB
17
18
Rated working voltage
Output power(Max.)
Output
Output voltage(selectable)
Output polarity
Output power & current (in common)
QTY. & capacity of battery
Unit dimension(mm)
Net weight(kg)
100~240Vac/50-60Hz
60W
3
4
USB interface
DC interface
5Vdc
9 / 12Vdc
2.0A / 10W
2200mAh*8
5 . How to use
*
Products specifications are subject to change without notice.
6 . Specifications
M
odel
Ratel 860P
5Vdc
Solar input
polarity
12
~
25Vdc | Up to 50W
Solar input
voltage range
252*146*45
0.94
standard
12VdcX4
5.0A/60W
2.0A/24W
POE interface
15Vdc / 24Vdc
+
4,5pins -7,8pins
1.0A/(15.8V16W)
or
(
24V24W)
RATEL
MICRO UPS with Li-Ion Battery
5mm socket
V2 16072020
1. High-capacity lithium batteries provide long backup to your loads.
2. High compatibility, the Ratel is suitable for most digital products on the
market.
3. USB output (5V) can supply charge for devices such as mobile phone, PSP,
IPod, MP4, etc.
4. Power Over Ethernet (POE) can transmit data and power simultaneously,
thus simplifiying the wiring.
5. Intelligent circuit design with over-charge, over-discharge and short-
circuit protection.
6. Built-in adapter allows wide AC voltage range (85 ~ 265Vac)
7. Built-in solar charger
1. High-capacity lithium batteries provide long backup to your loads.
2. High compatibility, the Ratel is suitable for most digital products on the
market.
3. USB output (5V) can supply charge for devices such as mobile phone, PSP,
IPod, MP4, etc.
4. Power Over Ethernet (POE) can transmit data and power simultaneously,
thus simplifiying the wiring.
5. Intelligent circuit design with over-charge, over-discharge and short-
circuit protection.
6. Built-in adapter allows wide AC voltage range (85 ~ 265Vac)
7. Built-in solar charger
1. In order to prevent over-discharge of the lithium batteries, please restart the
Ratel when AC power becomes available after low-battery cutoff.
2. Before connecting loads to the Ratel, it is essential that you check their nominal
working voltage, current and polarity, which you will find on their original
adapters.
3. The output power of this model is controlled by total power capacity. The total
power of the loads which connect to all the ports cannot exceed the maximum
output power of your model. If this does occur, the USB ports will be closed and
the status light will flash yellow. If the total power of the loads still exceeds the
maximum power rating after the USB ports are closed, all the output ports will
be closed, and all power indicator lights will flash. In this situation, please
remove excess loads.
4. Press and hold the power key for 2 to 3 seconds to boot up the Ratel. If the
output voltage indicator is green, this DC port is outputting voltage, and one
can select between 9V and 12V by sliding the DC voltage switch. After plugging
the Ratel into the grid, the status light will turn green to indicate the battery is
charging. 100% means the battery is fully charged. In the process of charging,
the power indicator light indicates the capacity of the battery in 25% increments
– 25%, 50%, 75% and 100%. When disconnected from the grid, the power
indicator lights will indicate the decreasing capacity of the battery in 25%
increments – 100%, 75%, 50% and 25%. When the indicator light at the 25%
marks begins to flash, this means that battery power is very low. Press and hold
the power key for 2 to 3 seconds to turn off the Ratel and stop output voltage.
5. The plug-and-play USB provides stable charging to digital products with their
original cables.
6. The Ratel will shut down automatically when it reaches low battery status; it will
restart with output power when the AC power is restored.
7. If the Ratel will not be used for extended periods, ensure that it is fully charged
before storing in a cool, dry place. If the Ratel has been in storage too long, you
will need to plug in grid power until the status light turns green. It is
recommended that the Ratel battery is charged once per month.
8. The built-in solar module has constant current and voltage control; it can charge
lithium batteries on startup or in shutdown state when connected to a solar
panel, and will supply power to your loads when your UPS is on.
1. In order to prevent over-discharge of the lithium batteries, please restart the
Ratel when AC power becomes available after low-battery cutoff.
2. Before connecting loads to the Ratel, it is essential that you check their nominal
working voltage, current and polarity, which you will find on their original
adapters.
3. The output power of this model is controlled by total power capacity. The total
power of the loads which connect to all the ports cannot exceed the maximum
output power of your model. If this does occur, the USB ports will be closed and
the status light will flash yellow. If the total power of the loads still exceeds the
maximum power rating after the USB ports are closed, all the output ports will
be closed, and all power indicator lights will flash. In this situation, please
remove excess loads.
4. Press and hold the power key for 2 to 3 seconds to boot up the Ratel. If the
output voltage indicator is green, this DC port is outputting voltage, and one
can select between 9V and 12V by sliding the DC voltage switch. After plugging
the Ratel into the grid, the status light will turn green to indicate the battery is
charging. 100% means the battery is fully charged. In the process of charging,
the power indicator light indicates the capacity of the battery in 25% increments
– 25%, 50%, 75% and 100%. When disconnected from the grid, the power
indicator lights will indicate the decreasing capacity of the battery in 25%
increments – 100%, 75%, 50% and 25%. When the indicator light at the 25%
marks begins to flash, this means that battery power is very low. Press and hold
the power key for 2 to 3 seconds to turn off the Ratel and stop output voltage.
5. The plug-and-play USB provides stable charging to digital products with their
original cables.
6. The Ratel will shut down automatically when it reaches low battery status; it will
restart with output power when the AC power is restored.
7. If the Ratel will not be used for extended periods, ensure that it is fully charged
before storing in a cool, dry place. If the Ratel has been in storage too long, you
will need to plug in grid power until the status light turns green. It is
recommended that the Ratel battery is charged once per month.
8. The built-in solar module has constant current and voltage control; it can charge
lithium batteries on startup or in shutdown state when connected to a solar
panel, and will supply power to your loads when your UPS is on.
WARNING:
1. Always check the working voltage, current and polarity of the
loads before connecting them to the Ratel, then choose the
corresponding voltage.
2. Charge device fully prior to initial use.
3. Damage caused by dropping, disassembling or attempting to
repair the Ratel privately will render your warranty null and
void.
4. Do not immerse the Ratel in water or allow it to get wet.
5. Do not dispose of any of the Ratel's components in fire.
6. Do not use the Ratel in flammable environments
7. Keep the Ratel out of reach of children and unauthorised
persons.
1. Always check the working voltage, current and polarity of the
loads before connecting them to the Ratel, then choose the
corresponding voltage.
2. Charge device fully prior to initial use.
3. Damage caused by dropping, disassembling or attempting to
repair the Ratel privately will render your warranty null and
void.
4. Do not immerse the Ratel in water or allow it to get wet.
5. Do not dispose of any of the Ratel's components in fire.
6. Do not use the Ratel in flammable environments
7. Keep the Ratel out of reach of children and unauthorised
persons.
Please do not disassemble, squeeze or short
circuit the batteries. Do not dispose of the
batteries by means of fire or water. Do not place
the Ratel in environments where temperature
exceeds 60
°
C (140
°
F)
Please do not disassemble, squeeze or short
circuit the batteries. Do not dispose of the
batteries by means of fire or water. Do not place
the Ratel in environments where temperature
exceeds 60
°
C (140
°
F)
POE LAN
INPUT
100-240Vac
SELECTOR
15V 24V
12V SOLAR
INPUT
SELECTOR OUTPUT
12V OUTPUT
9V
12V
{
}
1
2
Phone
WIFI
IPAD
PSP
Thank you for choosing the OMNIPOWER RATEL MICRO UPS.
Before operating this unit, please read the USER MANUAL
carefully to ensure the best possible performance is obtained.
1) OmniPower Ratel 860P
2) AC power cable
3) DC output cables (2 ends)
4) User's manual
5) Warranty card
1 . OMNIPOWER RATEL MICRO UPS package
1) ON/OFF Switch
2) Work status indicator
3) 12Vdc LED Indicator
4) 9Vdc LED Indicator
5) 25
%
BAT
capacity
LED
Indicator
6) 50
%
BAT
capacity
LED
Indicator
7) 75
%
BAT
capacity
LED
Indicator
8) 100
%
BAT
capacity
LED
Indicator
9) Ethernet output interface
(POE output: 15V/24V)
10) LAN Ethernet interface LAN
11) Output Voltage Selector(15V/24V)
12) 12Vdc solar input
13) Output Voltage Selector(9V/12V)
14) Output socket(9V/12V) 5mm
15) Output socket
16) AC input socket
17) Output socket 5V
18) USB (5Vdc) output
2 . Instructions of the components
3 . Features
4 . High compatibilities
2
3
4
5
7
8
6
1
9
10
11
12
13
14
15
16
Ratel 860P
5Vdc OUTPUT
USB
USB
17
18
Rated working voltage
Output power(Max.)
Output
Output voltage(selectable)
Output polarity
Output power & current (in common)
QTY. & capacity of battery
Unit dimension(mm)
Net weight(kg)
100~240Vac/50-60Hz
60W
3
4
USB interface
DC interface
5Vdc
9 / 12Vdc
2.0A / 10W
2200mAh*8
5 . How to use
*
Products specifications are subject to change without notice.
6 . Specifications
M
odel
Ratel 860P
5Vdc
Solar input
polarity
12
~
25Vdc | Up to 50W
Solar input
voltage range
252*146*45
0.94
standard
12VdcX4
5.0A/60W
2.0A/24W
POE interface
15Vdc / 24Vdc
+
4,5pins -7,8pins
1.0A/(15.8V16W)
or
(
24V24W)
RATEL
MICRO UPS with Li-Ion Battery
5mm socket
V2 16072020
1. High-capacity lithium batteries provide long backup to your loads.
2. High compatibility, the Ratel is suitable for most digital products on the
market.
3. USB output (5V) can supply charge for devices such as mobile phone, PSP,
IPod, MP4, etc.
4. Power Over Ethernet (POE) can transmit data and power simultaneously,
thus simplifiying the wiring.
5. Intelligent circuit design with over-charge, over-discharge and short-
circuit protection.
6. Built-in adapter allows wide AC voltage range (85 ~ 265Vac)
7. Built-in solar charger
1. High-capacity lithium batteries provide long backup to your loads.
2. High compatibility, the Ratel is suitable for most digital products on the
market.
3. USB output (5V) can supply charge for devices such as mobile phone, PSP,
IPod, MP4, etc.
4. Power Over Ethernet (POE) can transmit data and power simultaneously,
thus simplifiying the wiring.
5. Intelligent circuit design with over-charge, over-discharge and short-
circuit protection.
6. Built-in adapter allows wide AC voltage range (85 ~ 265Vac)
7. Built-in solar charger
1. In order to prevent over-discharge of the lithium batteries, please restart the
Ratel when AC power becomes available after low-battery cutoff.
2. Before connecting loads to the Ratel, it is essential that you check their nominal
working voltage, current and polarity, which you will find on their original
adapters.
3. The output power of this model is controlled by total power capacity. The total
power of the loads which connect to all the ports cannot exceed the maximum
output power of your model. If this does occur, the USB ports will be closed and
the status light will flash yellow. If the total power of the loads still exceeds the
maximum power rating after the USB ports are closed, all the output ports will
be closed, and all power indicator lights will flash. In this situation, please
remove excess loads.
4. Press and hold the power key for 2 to 3 seconds to boot up the Ratel. If the
output voltage indicator is green, this DC port is outputting voltage, and one
can select between 9V and 12V by sliding the DC voltage switch. After plugging
the Ratel into the grid, the status light will turn green to indicate the battery is
charging. 100% means the battery is fully charged. In the process of charging,
the power indicator light indicates the capacity of the battery in 25% increments
– 25%, 50%, 75% and 100%. When disconnected from the grid, the power
indicator lights will indicate the decreasing capacity of the battery in 25%
increments – 100%, 75%, 50% and 25%. When the indicator light at the 25%
marks begins to flash, this means that battery power is very low. Press and hold
the power key for 2 to 3 seconds to turn off the Ratel and stop output voltage.
5. The plug-and-play USB provides stable charging to digital products with their
original cables.
6. The Ratel will shut down automatically when it reaches low battery status; it will
restart with output power when the AC power is restored.
7. If the Ratel will not be used for extended periods, ensure that it is fully charged
before storing in a cool, dry place. If the Ratel has been in storage too long, you
will need to plug in grid power until the status light turns green. It is
recommended that the Ratel battery is charged once per month.
8. The built-in solar module has constant current and voltage control; it can charge
lithium batteries on startup or in shutdown state when connected to a solar
panel, and will supply power to your loads when your UPS is on.
1. In order to prevent over-discharge of the lithium batteries, please restart the
Ratel when AC power becomes available after low-battery cutoff.
2. Before connecting loads to the Ratel, it is essential that you check their nominal
working voltage, current and polarity, which you will find on their original
adapters.
3. The output power of this model is controlled by total power capacity. The total
power of the loads which connect to all the ports cannot exceed the maximum
output power of your model. If this does occur, the USB ports will be closed and
the status light will flash yellow. If the total power of the loads still exceeds the
maximum power rating after the USB ports are closed, all the output ports will
be closed, and all power indicator lights will flash. In this situation, please
remove excess loads.
4. Press and hold the power key for 2 to 3 seconds to boot up the Ratel. If the
output voltage indicator is green, this DC port is outputting voltage, and one
can select between 9V and 12V by sliding the DC voltage switch. After plugging
the Ratel into the grid, the status light will turn green to indicate the battery is
charging. 100% means the battery is fully charged. In the process of charging,
the power indicator light indicates the capacity of the battery in 25% increments
– 25%, 50%, 75% and 100%. When disconnected from the grid, the power
indicator lights will indicate the decreasing capacity of the battery in 25%
increments – 100%, 75%, 50% and 25%. When the indicator light at the 25%
marks begins to flash, this means that battery power is very low. Press and hold
the power key for 2 to 3 seconds to turn off the Ratel and stop output voltage.
5. The plug-and-play USB provides stable charging to digital products with their
original cables.
6. The Ratel will shut down automatically when it reaches low battery status; it will
restart with output power when the AC power is restored.
7. If the Ratel will not be used for extended periods, ensure that it is fully charged
before storing in a cool, dry place. If the Ratel has been in storage too long, you
will need to plug in grid power until the status light turns green. It is
recommended that the Ratel battery is charged once per month.
8. The built-in solar module has constant current and voltage control; it can charge
lithium batteries on startup or in shutdown state when connected to a solar
panel, and will supply power to your loads when your UPS is on.
WARNING:
1. Always check the working voltage, current and polarity of the
loads before connecting them to the Ratel, then choose the
corresponding voltage.
2. Charge device fully prior to initial use.
3. Damage caused by dropping, disassembling or attempting to
repair the Ratel privately will render your warranty null and
void.
4. Do not immerse the Ratel in water or allow it to get wet.
5. Do not dispose of any of the Ratel's components in fire.
6. Do not use the Ratel in flammable environments
7. Keep the Ratel out of reach of children and unauthorised
persons.
1. Always check the working voltage, current and polarity of the
loads before connecting them to the Ratel, then choose the
corresponding voltage.
2. Charge device fully prior to initial use.
3. Damage caused by dropping, disassembling or attempting to
repair the Ratel privately will render your warranty null and
void.
4. Do not immerse the Ratel in water or allow it to get wet.
5. Do not dispose of any of the Ratel's components in fire.
6. Do not use the Ratel in flammable environments
7. Keep the Ratel out of reach of children and unauthorised
persons.
Please do not disassemble, squeeze or short
circuit the batteries. Do not dispose of the
batteries by means of fire or water. Do not place
the Ratel in environments where temperature
exceeds 60
°
C (140
°
F)
Please do not disassemble, squeeze or short
circuit the batteries. Do not dispose of the
batteries by means of fire or water. Do not place
the Ratel in environments where temperature
exceeds 60
°
C (140
°
F)
Tel: +27 11 453 0924 I www.probegroup.co.za