background image

Phone Programming

Page 5

1.

You can program the phone on-site or remotely.

2.

If programming on-site, pull front assembly away from unit.

3.

Remove the cover of the NEMA 4 enclosure by loosening the 4 corner screws.

On-Site Programming:

Remote Programming:

Step 1: To Begin Program Mode

A. Press 

Enter

Step 2: To Program Emergency Numbers

A. Press 

1, Enter

, (phone number), 

Stop

Note:

 Press 2-5 in step 2A for emergency numbers 2-5 as needed

Step 3: To Program Location Message

A. To turn on message Press 

1, 3, Enter, 2

B. Press 

6, Record

 (speak message) 

Stop

 (to replay message 

Press 6, Play

)

C. For no message Press 

1, 3, Enter, 0

Step 4: To Program Auto Disconnect Time (Default is 5 minutes, lowest interval is 1 minute)

A. Press 

8, Enter,

 (3 digit number in minutes)

Ex:

 2 minutes = 002

Step 5: To Exit Program Mode

A. Press 

Stop 

for 3 seconds

Step 1: To Begin Program Mode

A. Call into phone by dialing the number of the Call Station

B. After first simulated ring, Press 

#, #

 (Wait for 4 tones)

C. Key in security code (Default is 1111) (Wait for confirmation tones)

Step 2: To Program Emergency Numbers

A. Press 

1, *, 

(Phone number), 

*, #

 (Wait for confirmation tones)

Note:

 Emergency numbers (2-5) repeat step 2A pressing (2-5) as needed

Step 3: To Program Location Message

A. To turn on message press 

1, 3, *, 2

 (Wait for confirmation tones)

B. Press 

6, *

, (Speak message) 

#, *, #

 (Wait for confirmation tones)

i. To replay message Press 

6, #

 (Wait for confirmation tones)

C. For NO message Press 

1, 3, *, 0

 (Wait for confirmation tones)

Step 4: To Program Auto Disconnect Time (Default is 5 minutes, lowest interval is 1 minute)

A. Press 

8, *,

 (3 digit number in minutes)

Ex:

 2 minutes = 002

Step 5: To Exit Program Mode

A. Press 

*, #, 0

 (You will hear a beep, beep) 

*, #

 (You will hear a buzz)

Keypad

Summary of Contents for 2100-EPV2 VoIP

Page 1: ...00 EPL2 Landline 120v Call Station 2100 EPV2 VoIP 120v Call Station N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www RATHCommunications com RP8500SCS Ver 3 10 17 Installation Operations Manual Made in the USA 2 Year Warranty ...

Page 2: ...remotely assist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business The RATH Team N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www RATHCommunications com Table of Contents Description Safety Guidelines Items Needed Installation Communication Phone Programmi...

Page 3: ...rage Be careful of finished surfaces during transport and installation to avoid damaging the finish Installation and maintenance should only be performed by qualified electricians It is recommended a minimum of 2 people perform installation Do not install phone during extreme weather conditions Do not touch uninsulated phone wires or terminals unless the phone line has been disconnected at the net...

Page 4: ...mmed remotely secure the front assembly to the back panel and reinstall the 8 screws to the sides of the unit If the phone will be programmed on site proceed to the directions for On Site Programming Communication Landline To connect your analog phone line to the Emergency Call Station 1 Remove front Stainless Steel plate using the security torx bit to remove the 6 security screws 2 Locate the gra...

Page 5: ...es Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number of the Call Station B After first simulated ring Press Wait for 4 tones C Key in security code Default is 1111 Wait for confirmation tones Step 2 To Program Emergency Numbers A Press 1 Phone number Wait for confirmation tones Note Emergency numbers 2 5 rep...

Page 6: ...proceed to the Troubleshooting Section Push the emergency button on the front of the Call Station Yes No RATH recommends the Call Station be tested on a regular basis to ensure proper operation Adjusting the Volume Volume Adjust VR1 Mic Sensitivity VR2 If the volume is too low or high adjust it by referring to the diagram and instructions below Note Refer to the instructions under Programming the ...

Page 7: ...em is not providing a disconnect signal Contact the appropriate party to make sure the disconnect signal is provided When the called party hangs up busy signal is heard through speaker Phone company or phone system is not providing a disconnect signal Operator needs to press to disconnect the call Disconnect time on phone needs to be lowered see page 6 Call Station appears non functional Strobe do...

Page 8: ...8 0 9 6 3 2 Enter Record Play Pause Stop Constant Strobe y r e t t a B Communication Source FRONT COVER Note If using landline phone cable will just run out of the bottom of the NEMA 4 enclousre 120v r e m r o f s n a r T LN G Wago Connector ...