Powering the SmartRescue

Step 5: Powering the SmartRescue

There are 3 options for powering the SmartRescue:

Option 1: Plug-In Transformer (2500-205 & 2500-210 models only)

   • Plug transformer into a standard 120vac outlet

Option 2: Hard-Wired Transformer

   • Connect the hot wire of the 120vac to the L screw

   • Connect the neutral wire of the 120vac to the N screw

   • Connect the ground wire of the 120vac to the ground screw

   • Connect one lead of the dc power connection to the -V screw and the other to the +V screw

   • Connect the other side of the dc power connection to the 24v power input on the lower left side of the 

     SmartRescue (polarity is not important)

Option 3: 2500-PWR24U Power Supply (Area of Refuge applications only)

   • Use 1 pair, 18 AWG wire for power (maximum distance is 5,100’)

   • Connect one wire to the positive side of distribution block within the 2500-PWR24U, and the other wire to 

     the negative side

   • Connect the other side of wires to the 24v power input on the lower left side of the SmartRescue board   

     (polarity is not important)

   

Note:

 Do not use the plug-in or hardwired transformer when using the 2500-PWR24U.

Page 4

Provided 

by RATH®

Provided 

by RATH®

Summary of Contents for 2500-205B

Page 1: ...SmartRescue 5 10 Installation Operations Manual N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www rathcommunications com RP8500510 Ver 4 11 19 WARRANTY 2YEAR...

Page 2: ...ations com Table of Contents SmartRescue 5 10 Installation Powering the SmartRescue Wiring Emergency Phones to SmartRescue Typical Wiring Diagrams for Elevators Typical Wiring Diagram for Areas of Ref...

Page 3: ...s Pre Installation Requirements Step 1 Remove the front cover from the SmartRescue and mount the SmartRescue back box to the wall using suitable mounting screws not included Step 2 Punch out the condu...

Page 4: ...d 120vac outlet Option 2 Hard Wired Transformer Connect the hot wire of the 120vac to the L screw Connect the neutral wire of the 120vac to the N screw Connect the ground wire of the 120vac to the gro...

Page 5: ...phone line is 600 ohms Step 7 Mount the front cover back on to the enclosure Emergency Phone Yellow PIN 1 Green PIN 2 Red PIN 3 Black PIN 4 Diagram B 0 2 5 3 1 4 6 7 8 9 0 2 5 3 1 4 6 7 8 9 0 2 5 3 1...

Page 6: ...SPECIFIC PHONE IF THE GREEN LED IS LIT YOU WILL JOIN CONVERSATION 6 PRESS TALK HOLD BUTTON AGAIN TO PLACE CONVERSATION ON HOLD 7 PRESS RED DISCONNECT CALL TO RESCUE SERVICES BUTTON TO END EXTERNAL CAL...

Page 7: ...HOLD 7 PRESS RED DISCONNECT CALL TO RESCUE SERVICES BUTTON TO END EXTERNAL CALL ANY PHONE AND SUB MASTER ORIGINALLY TALKING REMAIN IN CONVERSATION WITH THIS UNIT 8 HANG UP HANDSET TO END CALLS TO PHON...

Page 8: ...VED EMERGENCY PHONE SOLID LIGHT C ALLING BLINKING LIGHT RECEIVED EMERGENCY PHONE SOLID LIGHT C ALLING BLINKING LIGHT RECEIVED EMERGENCY PHONE Typical Wiring Diagram for Area of Refuge Applications 1 P...

Page 9: ...rgency Number as entered in b Stop 4 To exit program mode press and hold Stop for 2 3 seconds until warble sound Program the Location Message Note This is always done unless your Call Center requests...

Page 10: ...hone that placed the call c If call is not answered at the SmartRescue the Emergency Phone will hang up and dial the second number programmed into the phone d The Rescue Services LED located next to t...

Page 11: ...6 9 TB1 Relay SmartRescue System Activation Relay When an Emergency Phone has been activated this relay changes from NO to closed It can be connected to a strobe or other notification means Connectio...

Page 12: ...SmartPhone is correct Two way communication from SmartPhone is poor There could be feedback on the line Adjust the VR1 and VR2 Verify wiring is not spliced onto the phone line cord SmartRescue will n...

Page 13: ...or indoor use only Operating temperature 32 F to 120 F 0 C to 49 C TB1 Relay Load Current 130mA Load Voltage 350vdc or vac Note Input power circuit battery circuit and phone circuits are supervised in...

Page 14: ...61 294 96 1 03 26 25 1 27 32 38 0 32 8 05 0 88 22 23 4 34 110 17 0 45 11 41 0 50 12 70 1 0 56 319 09 11 61 294 96 0 33 8 49 5 81 147 48 0 28 7 18 FRONT PANEL COVER LEFT SIDE BOTTOM SIDE CONTROL INSIDE...

Page 15: ...ED Y G R B Y G R B Y G R B Y G R B Y G R B Y G R B Y G R B Y G R B Y G R B Y G R B 1 2 3 4 5 6 7 8 9 10 HOOK SWITCH Y G R B Y G R B 0 69 17 50 0 84 21 27 0 69 17 46 0 69 17 46 0 25 6 35 0 13 3 18 4 02...

Reviews: