background image

Sensor Board

User Manual

ver. 1.0

Summary of Contents for Sensor Board

Page 1: ...Sensor Board User Manual ver 1 0 ...

Page 2: ...ning This is NOT the user manual of the iX3M dive Computer This is an intagration about the optional sensor board for iX3M Reb You can download the iX3M user manual from www ratio computers com support area ...

Page 3: ...aining and should be used only by those divers who have been appropriately trained by a certified diver training organization To completely understand the terminology used in this document and the functions of the dive computer a proper diving training is required ...

Page 4: ...4 Think Green If possible do not print this manual Use your tablet or your PC to read it ...

Page 5: ...nger Warning Models of Sensor Board Connect the iX3M to the Sensor Board 11 Sensors of the Rebreather Sensor Board 11 Sensor Board iX3M Reb iX3M in CCR mode 12 Activate the CCR mode 13 Activate la Sensor Board 14 iX3M with Sensor Board during the dive ...

Page 6: ...lating to the diving itself Even a careful reading of this manual and the use of this device don t prevent possible dangers Anyone who doesn t know or doesn t accept consciously these risks must not dive with iX3M computer Diving has some intrinsic risks which cannot never be completely eliminated No computer or diving chart can guarantee that the risk of Decompression Sickness DCS or Oxygen toxic...

Page 7: ...ch Never share a unique computer for two divers while diving every diver must have his her device at his her wrist which can give information to him her only Never dive with a computer which has not taken into consideration the previous dives a diver made the computer calculation CANNOT use unknown data or take into consideration dives which it has not done ...

Page 8: ...d clearly Check always that settings are the ones desired Don t let the computer be manipulated by someone else before diving In this case check that settings are the ones you desire Consider that our body experience changes everyday The computer cannot take into consideration all these changes If you don t feel at your best physical conditions or if you feel physical problems don t dive Avoid all...

Page 9: ...his could be longer than the one visualised according to some parameters calculated by the computer during the whole dive Trying to ascend at the correct speed and respect the visualised depth of the stops helps to respect this time Respect always the No FLY Time never take a plane if the No FLY Time icon is still visible on the screen Remember to plan the last dive of the series taking into consi...

Page 10: ... of your Rebreather in order to know the required technical specifications screw pitch number of sensors etc If you would like to use a Sensor Board with analogical Fisher plug the dedicated RATIO adapter Analogical Digital is required Example of Sensor board with 3 Oxy Molex connector your sensor board could be different Example of Sensor board with SMB Molex connector your sensor board could be ...

Page 11: ...Reb Remove the protection cap from the iX3M Reb Warning in order to use the iX3M reb without the Sensor board the protection cap is needed Diving without a sensor board or the protection cap will cause the flooding of the unit Plug the sensor board as shown in the picture Always check that the red dot on the connector of the sensor board and the red dot on the connector of the iX3M Reb match up In...

Page 12: ...al in order to use the iX3M in CCR mode without using the Sensor Board The main manual of the iX3M is available at this link http www ratio computers com support To reach this menu from the main screen press in sequence CCR settings ccr mode setpoint low depth 1 setpoint med depth 2 setpoint high SETpoint mode b A C D Exit NEXT VALUE _ off 0 70 20 m 1 00 50 m 1 40 AUTO A b D D ...

Page 13: ...to SAVE 02 and save the values pressing C or D Press A to exit Warning Saving the values is required in order to let the Sensor board works properly The calibration of the sensors is done in air Do not calibrate the sensors in a closed environment or in polluted air Refer to the producer of your Rebreather in order to know the calibration procedure requirements of your Rebreather model The iX3M wi...

Page 14: ... Sensor Board during the dive During the dive the data detected by the Sensor Board will be shown on the left part of the screen as shown in the picture If one or more Sensor are not active the symbol will be shown ...

Page 15: ...ou to dive with a Rebreather Divingwith Rebreatherwithoutasuitabletrainingorwithouttheduecautioncancauseinjuriesordeath This document DOES NOT replace an adequate diving training and should be used only by those divers who have been appropriately trained by a certified diver training organization ...

Page 16: ... 2016 The reproduction even partial without stated approval is severely prohibited RATIO Computers ...

Reviews: