Before installation, note the following:

 

Unpack the box, remove the plastic packaging of the dispenser and make 

sure that the following parts are included 

(Fig. 6)

:

 

1 x Dispenser with mounted plastic disposable pump 

(Fig. 5)

 

1 x Arm lever 

(Fig. 2)

 

1 x Wall mounting plate 

(Fig. 3) 

not necessary for stand alone use

 

1 x Colored drip tray (clip-on) 

1 x Bag with one set of three screws and dowels and 

one metal strip

 

1 x Instruction manual 

 

 

1  Installation / Operation    

1 a Assembling the dispenser

 

 

For reason of space s, the dispenser is supplied with the drip tray and arm lever 

removed 

(Fig. 1).

 

 

Insert the arm lever on the back of the dispenser and push it in until you 

hear it lock in place 

(Fig. 2)

; important: then insert the metal strip 

(serves 

to secure the arm lever and as the upper attachment point of the 

dispenser on the wall mounting plate).

 

 

The dispenser can be used as a stand-alone unit as well as wall-mounted. 

1

 

b Mounting the dispenser (Fig. 3)

 

For wall mounting, a drilling machine and a 6mm drill as well as a 

(cordless) screwdriver is required. The wall mounting plate can serve as a 

drilling template. When exchanging the dispenser, the existing wall 

mounting plate can be used under certain circumstances.  

 

Select suitable mounting location and height. Recommended height: The 

top edge of the dispenser should be approx. 130 cm above the floor. 

Leave enough space under the dispenser so that the cover of the 

dispenser housing (possibly with drip tray attached) can be opened 

completely for easy bottle exchange. 

 

Fasten wall mounting plate with dowels and screws. Optionally, the Tesa 

fastening solution article no. SD2005-78 can be used (additional charge). 

 

Slide the dispenser over the wall mounting plate from above until the 

locking tongue audibly engages. 

 

2

 

Operation

 

 

Open the dispenser by pressing the pushbutton at the top under 

the arm lever 

(Fig. 2) 

and fold the lid forward

 

 

Slide the full bottle over the dispenser pump from below and 

insert it into the housing 

(Fig. 4)

; close the housing cover and 

attach the drip tray. 

 

When using the pump for the first time, press the arm lever down 

several times until liquid emerges at the pump nozzle; when using 

highly viscosity gels, soaps or lotions, the lever must be pressed 

down up to 10 times vigorously before liquid emerges! 

If this 

measure is not successful, use thin liquid media (water or 

disinfectant) first to fill the tube and then place in the bottle with 

the viscous material. 

 

 

 

 

3

 

Bottle or pump exchange and dosage

 

 

Open the dispenser (see under 2), pull the empty bottle forward and 

remove it, remove the pump. Loosen the locking device of the pump 

on the wall side of the body. Dispose of the pump.

 

 

Insert new pump and proceed as described under 2

 

 

On delivery the dispenser pump is set to the maximum dosing 

quantity of 1.8 ml per stroke.

 

 

When using dense liquid, please only pump new pumps with the 

maximum setting (dosing quantity 1.8 ml)! 

 

By moving the dosing fork to the right or left, the dispensing 

quantity can be reduced to 1.2 ml or 0.8 ml per stroke 

(Fig. 5)

 

 

4

 

Operation with adapter for Ophardt DHP pumps 

 

Open dispenser (see under 2), remove bottle and existing pump (see 

under 3) 

 

Slide the adapter into the guide rail from the front like a pump until 

the lugs of the spring clips abut the guide rail on both sides. 

 

Slightly compress the spring on both sides so that the nose can pass the 

guide rail at the side 

 

The adapter can now easily be pushed further into the guide rails up 

to the rear wall until it snaps into place on the mounting lug of the 

rear wall like the pump. 

 

Insert Ophardt DHP pump and bottle, close the dispenser 

 

5

 

Cleaning the dispenser | Hygiene recommendations

 

 

The dispenser is basically maintenance-free, but the advantages of 

dosing dispensers are only guaranteed if the dispensers are cleaned 

and disinfected regularly. Inadequate dispenser hygiene can lead to 

germ colonisation of the dispenser system. Disinfection or soap 

residues in the pump or at the nozzle can also cause problems. 

Therefore, the dispenser should be regularly cleaned and possibly 

disinfected according to the recommendations for infection 

prevention and hygiene. 

 

For this purpose, clean the housing only with mild detergent, if 

desired, treat with surface disinfectant.

 

 

The housing can be cleaned in a suitable dishwasher

 

 

The

 Robert Koch 

Institute expressly recommends the use of 

disposable bottles or hygiene containers for washing and care 

products. For hand disinfectants, the German Drug Law applies: A 

refilling of empty bottles may only be carried out by a pharmacy 

under aseptic conditions. 

 

For hygienic reasons, the dispenser pump is designed as a disposable 

pump which should be replaced at regular intervals with bottle 

changes, at the latest every 3-4 months. The pumps must not be 

reprocessed, but must be replaced. The pumps are available as jet, 

spray or foam version (see 6.)

 

 

 

 