5 | Setup
40 / 96
80.06.083_iCombiPro-iCombiClassic_IM_en-US
2. Slide the floor device into the foot locks.
5.3.3 Align mobile oven rack
WARNING
The maximum approach angle of the entry ramp is exceeded
Risk of burns due to hot liquid and food being cooked at too steep an
approach angle.
Make sure that the approach angle of the entry ramp is less than 4 degrees.
NOTE
Malfunction due to inclined mobile oven rack
An incorrectly aligned mobile oven rack can lead to malfunctions in the
device function, for example during cleaning.
Align the mobile oven rack horizontally in the device.
1. Set a distance of 205 mm [8 1/8 inch] between the upper edge of the en-
try frame and the floor using the feet. The distance is required so that the
mobile oven rack can move correctly into the device.
Summary of Contents for iCombi Pro
Page 1: ...iCombi Pro iCombi Classic CombiMaster Plus Original installation instructions...
Page 93: ......
Page 94: ......
Page 95: ......