Interface PCB A1
X7
Power input to ON/OFF switch
X10
Central dial
X102 Touch
X150
X151
X152
X153
Data cable CPU (X107)
X154
Data cable TFT
X155
X158
Main PCB A2
X1
Pressure sensor P1
- 12V DC
X2
Thermocouple B3.1 - 3.6 core probe
X3
Thermocouple B1 cabinet
X4
Thermocouple B2 quenching
X5
Thermocouple B4 humidity
X6
Thermocouple B5 steam generator
X8
Loud speaker T2
- 12V AC
X11
Solenoid Y5 Clima
- 12V DC
X12
Level electrode S2
- 12V AC 600Hz
X13
Cabinet light
- 11.5V AC
X14
Power supply from transformer T1:
- 11.5V AC, 18V AC
X15
CDS Sensor
- 12V DC
X16
X18
SC Pump M4, Cleanjet Pump M6
X19
Solenoid Y1, Y2, Y3
X20
Energy optimising (Sicotronic)
- link on 2-4
X21
230V Power input
X23
UltraVent without Bus (USA only)
X24
SSR
- 12V DC
X25
Drain valve M7, Micro switch S12
- 12V DC
X26
X27
Door contact S3
- 12V DC
X29
X30
X51
Bus cable
X54
USB connection
X60
SD card slot
X75
cooling fan M5, Care Pump M12, Solenoid valve Y4
X106
Ethernet connection
X107
Data cable Interface PCB (X153)
F1
2A slow 230V power input X21
F2
2A slow 230V power input X21
LED Code CPU:
LED V10:
Internal power supply 3,3V processor ok
if V10 off and V68 ok - change PCB
LED V68:
18V power supply from T1 ok
if V68 off - check connection, change transformer T1