- 57 -
V02 en, SCC_WE
Only use the Original Rational USB Stick for Software update of SCC_WE units.
(Note: Most of the standard USB sticks can not be used for software update.)
The Rational USB Stick can be ordered with service part number: 87.01.084.
Software can only be updated to a higher version.
NOTE: The duration of a complete software update can last up to 10 miunutes!!
Please follow below instructions!
Software update can be done by the customer as follows::
Connect the USB stick with the USB interface at the bottom left hand cor-
ner of the control panel.
Press the key Communication, USB and update.
For standard update proceed as follows:
1.
Switch unit on
2.
Wait unitl the user interface is shown on the display.
3.
Connect the USB stick with the latest software version with the USB interface at the bottom
left hand corner of the control panel.
4.
Switch unit off and on again.
The unit will display „Update“
Only remove the USB stick after the display has changed again to the standard SCC display.
Please always make sure your customer has the latest software version on his appliance.
SCC Software update
Funktionstaste
Settings
HACCP
Service
Display configuration