UV-USA_CAN SCC_WE, CM_P V06, 11/2016
13
Piece of paper
Diff. press. switch
21
22
4. Setting of the differential pressure switch:
After the Ultravent has been installed, the
differential pressure switch must be adjusted to
the ambient conditions:
a) Connect Ultravent and Combi Steamer to mains.
b) Switch on Ultravent and Combi Steamer; select
cooking mode, time, temperature and open
unit’s door (high speed operation).
c) Set adjusting disc of the pressure switch to
zero position.
pic. 21
In case of pressure switch of company Honey
well back out screw
d) Block two third of the surface of the filter area
with a piece of paper (= reduction of air flow to
75%).
pic. 22
e) Turn adjusting disc of the pressure switch out
of the zero position, until the combi steamer
cuts out (yellow LED lights "filter on").
f) Remove the piece of paper. Now the combi
steamer should run again (only green LED lights).
g) Reassemble the unit and perform a test run.
Rear side of Ultravent
ATTENTION
During the entire adjustment procedure make sure
that the charcoal filters and stainless steel fat filter
grills remain positioned. Otherwise the filter switches
(which are located behind the filters) will set the