Error: ± 1km/h; (The speed limit for power and turning is equal).
Note: The value here is based on kilometers.
When the unit setting is converted from kilometers to miles, the speed value of the display interface
automatically converts to the correct mile value, but the speed limit value data set at this menu under the
mile interface is not converted. Is inconsistent with the actual speed limit of the mile speed.
P09: zero start, non-zero start setting, 0: zero start; 1: Non-zero start.
P10: The drive mode is set to 0: Power Drive (how much power is output is determined by the power file
bit and the switch is invalid at this time).
1: Electric drive (by turning the handle drive, the power file bit is invalid at this time).
2: Power Driven and Electric Driven Coexistence.
P11: Help sensitivity setting range: 1-24.
P12: Help start intensity setting range: 1-5.
P13: Power Magnetic Steel Disk Type Setting 5, 8, 12 Magnetic Steel Types.
P14: Controller limit value set default 12A range: 1-20A.
P15: Controller under voltage.
P16: ODO zero setting length press key 5 seconds ODO zero
P17:0: No enabling cruising, 1: enabling cruising; Automatic cruise optional (valid for protocol 2 only)
P18: Display speed ratio adjustment range: 50 % ~ 150 %,
P19: 0 power bit, 0: 0 file, 1: does not include 0 file
P20:0:2 Protocol 1:5 S Protocol 2: Standby 3: Standby