Fig. 23: Test/diagnosis; Example: Distance Control
No.
Designation
Description
1
Status of the Distance Controller
•
1/3: Manual mode
•
2/4: Automatic mode
•
255 / 0: Controller is still starting up and
initializing.
•
120: Controller cannot be reached/does
not respond.
2
Error bits 1 and 2 of the Distance Controller
•
Bit 1: Distance Control error
•
Bit 2: Distance Control status
u
Check to make sure that all cables and
other lines (hydraulic system, sensors,
etc.) are connected correctly and in
proper condition.
u
For all other sources of error, register
with the customer service department
and provide the error code.
3
Current height of left/right boom end section
If the value 65535 is displayed, there is no
communication to the controller (ECU-Mode
120)
4. Operation
AERO ISOBUS
5903001
45
Summary of Contents for AERO ISOBUS
Page 16: ...2 3 Structural menu overview 2 Layout and function 16 5903001 AERO ISOBUS...
Page 65: ......
Page 66: ......