No. Message in display
Meaning and possible cause
29 The agitator motor is overloaded.
The agitator is blocked.
•
Blockage
•
Defective connection
30 The discs shall be activated before opening the
metering sliders.
Correct software operation
•
Start spreading discs
•
Open metering slides
31 Idle measurement is necessary for EMC
calculation.
Alarm message before the idle measurement
•
Activate spreading disc start.
32 Externally controlled parts can be moved.Risk
of injury through squeezing and shearing! -
Direct ALL persons out of the danger zone -
Read the instruction manual Confirm with
ENTER
If the machine control unit is activated,
components may move unexpectedly.
•
Follow the displayed instructions only if all
risks have been eliminated.
33 Stop the discs and close the metering sliders
You may only switch to the System / Test menu
area if the spreading operation has been
deactivated.
•
Stop spreading discs.
•
Close the metering slide.
39 Manual mode active. Risk of fertiliser overflow. The message is displayed on switching over
from automatic to manual.
45 Error at M-EMC sensors. EMC control
deactivated!
The sensor has stopped sending signals.
•
Cable breakage
•
Defective sensor
46 Spreading speed error. Observe spreading
speed of 450..650 rpm!
The PTO speed is outside the range for the
M EMC function.
47 Left dosing error, hopper empty, outflow
blocked!
•
Hopper empty
•
Outlet blocked
48 Right dosing error, hopper empty, outflow
blocked!
•
Hopper empty
•
Outlet blocked
49 Idle meas. implausible. EMC control
deactivated!
•
Defective sensor
•
Defective transmission
50 Idle meas. impossible. EMC control
deactivated!
PTO speed not permanently stable
7. Alarm messages and possible causes