No. Message in display
Meaning and possible cause
79 Cover open!
Switch is not operated, the overloading function
is not possible.
The safety hood is open and not properly
closed.
80 Stop loading!
The message is displayed on switching over to
the system/test menu during operation.
•
Stop spreading operation.
•
Access the menu System / Test.
81 Low oil level!
Insufficient oil level in the hydraulic circuit.
•
Stop the machine and refill oil.
82 Type of machine modified. Spreading error
possible. New configuration required!
The operating modes cannot be combined with
certain machine types
u
Restart the machine control unit when
changing machine type.
u
Implement machine settings.
u
Load fertilizer chart for the machine type.
83 Reduce oil temp.
The oil temperature of the on-board hydraulic
system has reached the preset alarm limit.
88 Error at disc speed sensor
The spreading disc RPM could not be
determined
•
Cable breakage
•
Defective sensor
89 Disc speed too high
Alarm of the spreading disc sensor
•
The maximum RPM is reached.
•
The set RPM exceeds the maximum
admissible value.
90 AXMAT-Stop
The AXMAT function is automatically
deactivated and no longer regulates.
•
More than 2 sensors are reporting an
error.
•
Communication error
7. Alarm messages and possible causes