Sub-menu
Meaning
Description
Working width (m)
Determination of the working width to
be spread
4.6.2 Setting the working width
Flow factor
Input of flow factor of the fertilizer used
Normal disc speed
Input of the desired spreading disc
speed
Influences the EMC mass flow control
Spreading disc
Setting of the disc type mounted on the
LIME-PowerPack
Note: The spreading discs Sxx only
apply to the AXIS-PowerPack AXIS-
PowerPack
Selecting a type:
•
U2
Bound. sprd.type
Selection list:
•
Limited bd
•
Full bord.
Selection with arrow keys,
confirmation with the Enter key
Bound. disc speed
Pre-setting the RPM in the boundary
spreading mode
To be entered in a separate
input window
Limit. bd rate (%)
Pre-setting the application rate
reduction in boundary spreading mode
To be entered in a separate
input window
4.6.1
Application rate
In this menu, you can enter the target value for the desired application rate.
Entering the application rate:
u
Access the menu Fertiliser settings > Appl. rate (kg/ha).
The currently applied application rate is displayed.
u
Enter the new value in the input field.
u
Press
OK
.
The new value is saved in the machine control unit.
You can also enter or adjust the application rate directly via the working screen.