In the automatic mode, the operating lights are switched on as soon as the metering slides open and
the spreading process starts.
u
Access the menu Main menu > SpreadLight.
u
Put a check mark in the menu item SpreadLight AUTO [3].
The operating lights are switched on when the metering slides open.
u
Enter a turn off duration [1] in seconds.
The operating lights will switch off at the end of the entered time, if the metering slides are closed.
Range from 0 to 100 seconds.
u
Remove the check mark in the menu item SpreadLight AUTO [3].
The automatic mode is deactivated.
Manual mode:
In the manual mode, the operating lights can be switched on and off.
u
Access the menu Main menu > SpreadLight.
u
Put a check mark in the menu item Activate [2].
The operating lights are activated and remain on until you remove the check mark or leave the menu.
4.13
Special functions
4.13.1
Changing the system of units
Your system of units has been preset at the factory. However, the system can be changed from metric
to English units at any time.
Due to the great variety of different ISOBUS-compatible terminals, this chapter is limited to the
functions of the electronic machine control system without indicating a specific ISOBUS terminal.
•
Please observe the instructions for the operation of your ISOBUS terminal in the
corresponding operator's manual.
u
Open the Settings menu for the terminal system.
u
Access the menu Unit.
u
Select the desired unit system from the list.
u
Press OK.
All values of the various menus are converted.
Menu/value
Conversion of metric to imperial units
kg left
1 x 2.2046 lb.-mass (lbs left)
4. Operation
76
5901646
AXENT ISOBUS
Summary of Contents for AXENT 100.1
Page 6: ...Table of contents 6 5901646 AXENT ISOBUS...
Page 21: ...2 3 Structural menu overview 2 Layout and function AXENT ISOBUS 5901646 21...
Page 22: ...2 Layout and function 22 5901646 AXENT ISOBUS...
Page 113: ......